2301A Electronic Load Sharing and Speed Controls
The Electronic 2301A Load Sharing and Speed Control Series from Woodward controls the speed or load of diesel or gas engines, or steam or gas turbines. These units are housed in a sheet-metal chassis and consists of a single printed circuit board. The 2301A Speed Control provides control in the isochronous mode with droop available through an externally wired potentiometer.
The Electronic 2301A Load Sharing and Speed Control Series from Woodward controls the speed or load of diesel or gas engines, or steam or gas turbines. These units are housed in a sheet-metal chassis and consists of a single printed circuit board. The 2301A Speed Control provides control in the isochronous mode with droop available through an externally wired potentiometer.
Part Number | Description | Manuals | Stock Level |
---|---|---|---|
8272-608 | Woodward part 8272-608 series 2301A Load Sharing and Speed Control. Power does not need to be from a distribution point, part is CSA certified, and the primary speed control is N2. | Call for Availability | |
8272-609 | Woodward part 8272-609 series 2301A Load Sharing and Speed Control. High voltage range of 90-150 Vdc to 85-132 Vac, power nominal of </= 15 W. | Call for Availability | |
8272-610 | Woodward part 8272-610 series 2301A Load Sharing and Speed Control. Allows for automatic generator loading and isochronous load sharing, used for rated and idle speeds of prime movers. | Call for Availability | |
8272-611 | Woodward part 8272-611 series 2301A Load Sharing and Speed Control. Speed trim of 0-100 Omega for 0-10% speed change, speed selection through open terminals. | Call for Availability | |
9900-430 | Woodward 9900-430 series 2301A Load Sharing and Speed Control. Optional deceleration ramp, with a rated speed control of 11,450 Hz. | Call for Availability | |
9900-431 | The 9900-431 model is a 24-Volt Reverse-Acting Load Sharing and Speed Control Manufactured by Woodward Inc. This model is part of the 2301A series. The speed and load-sharing features of the 9900-431 model will be controlled by gasoline or diesel engines. | Call for Availability | |
9900-432 | 9900-432 is a forward-acting, 110V Woodward 2301A series load sharing and speed control. | Call for Availability | |
9900-433 | Woodward part 9900-430 series 2301A Load Sharing and Speed Control. Operates as a 110 V reverse-acting control, and works well in isochronous/droop mode. | Call for Availability | |
9903-106 | Woodward Motor Operated Potentiometer (MOP) Model 9903-106. Rated for 115V/60HZ/5W/1RPM for Woodward 2301, 2301A, 2500, and Electrically Powered Governor (EPG) Control Series. | In Stock Ships Today | |
9903-327 | Woodward part 9903-327 series 2301A Load Sharing and Speed Control. Accessible in reverse/forward acting controls, actuator output 7.5 Vdc max. | Call for Availability | |
9905-020 | Woodward's Part 9905-020 from 2301A Load Sharing and Speed Control Series. Powered by 20-40 Vdc input and is an individual actuator control. | In Stock Ships 3-5 Days | |
9905-021 | Model 9905-021 2301A Series Load Sharing and Speed Control. Load sharing input of 0-6 VDC, can be used with a steam turbine or gas engine. | In Stock Ships 3-5 Days | |
9905-022 | Woodward Part 9905-022 2301A Load Sharing and Speed Control. Operates with an actuator current of 0-400 mA, needs a minimum power factor of 0.9. | In Stock Ships 3-5 Days | |
9905-023 | 9905-023 is a reverse-acting, low-voltage Woodward 2301A control with a 0-400mA actuator current. | Call for Availability | |
9905-024 | Woodward model 9905-024 from series 2301A Load Sharing and Speed Control. Forward-acting model, actuator current of 0-200 mA, with dual actuators. | Call for Availability | |
9905-025 | 9905-025 is a low-voltage, reverse-acting 2301A load sharing and speed control with a tandem actuator. | Call for Availability | |
9905-026 | 9905-026 is a low-voltage, forward acting load sharing and speed control in Woodward's 2301A series. | In Stock Ships 3-5 Days | |
9905-027 | Woodward Part 9905-027 series 2301A Load Sharing and Speed Control | Call for Availability | |
9905-028 | Woodward 9905-028 2301A Series Load Sharing & Speed Control. Rated for use in ordinary locations, used with diesel or gasoline engines. | In Stock Ships 3-5 Days | |
9905-029 | Woodward part 9905-029 series 2301A Load Sharing and Speed Control. Offered with a deceleration ramp, reverse acting, and an individual actuator. | In Stock Ships 3-5 Days | |
9905-030 | 9905-030 is a forward-acting, high-voltage Woodward 2301A series load sharing and speed control device. | In Stock Ships 3-5 Days | |
9905-031 | 9905-031 is a reverse-acting, high-voltage Woodward 2301A series load sharing and speed control. | In Stock Ships 3-5 Days | |
9905-032 | Woodward part 9905-032 series 2301A Load Sharing and Speed Control. Operates on 0-400 actuator current, and can be used with steam or gas turbines. | Call for Availability | |
9905-033 | Woodward part 9905-033 series 2301A Load Sharing and Speed Control. Can be used in isochronous or droop mode, a reverse-acting model. | Call for Availability | |
9905-034 | 9905-034 is a high-voltage, forward-acting 2301A series Woodward load sharing and speed control with a tandem actuator. | Call for Availability | |
9905-035 | 9905-035 is a reverse-acting, high-voltage Woodward 2301A load sharing and speed control. | Call for Availability | |
9905-036 | 9905-036 is a forward-acting, high-voltage Woodward 2301A model with a 0-20mA actuator signal output. | Call for Availability | |
9905-037 | 9905-037 is a high-voltage, reverse-acting, single actuator Woodward 2301A load sharing and speed control. | Call for Availability | |
9905-038 | 9905-038 is a forward-acting, single actuator 2301A load sharing and speed control with a deceleration ramp. | Call for Availability | |
9905-039 | Woodward Part 9905-039 Series 2301A Load Sharing and Speed Control. Model is offered with a deceleration ramp, and can be used with diesel engines. Actuator output 7.5 Vdc max for 0 to 214 mA. | Call for Availability | |
9905-068 | Woodward part 9905-068 series 2301A Load Sharing and Speed Control. Operates under no less than 15 W nominal and a 20-40 VDC power supply. | In Stock Ships Today | |
9905-131 | Woodward part 9905-131 series 2301A Load Sharing and Speed Control. Model is compatible with an SPM synchronizer, temperature range of –40 to +185 °F. | In Stock Ships 3-5 Days | |
9905-132 | Forward-Acting Standard Speed Control 9905-132 from Woodward for the 2301A Load Sharing and Speed Control Series | Call for Availability | |
9905-133 | Woodward part 9905-133 series 2301A Load Sharing and Speed Control. Operating range of 90-240 Vrms, a vibration of 5-500 Hz, preset speed of 2000-6000. | Call for Availability | |
9905-134 | Reverse Speed Control 9905-134 from Woodward. Reverse Speed Control for the 2301A Electronic Speed Control Series. | Call for Availability | |
9905-135 | Woodward model 9905-134 series 2301A Load Sharing and Speed Control. Time-continuous compatibility of 0-500 ms, CSA certified, has a selectable speed control range. | Call for Availability | |
9905-136 | Woodward part 9905-136 series 2301A Load Sharing and Speed Control. Can be used with MPU, and required use with twisted conductor shield cable. | Call for Availability | |
9905-137 | Woodward model 9905-137 series 2301A Load Sharing and Speed Control. Can be used with diesel/gasoline engines, acceleration ramp speed of 0-10s, and droop adjustment of 0-10%. | Call for Availability | |
9905-138 | Woodward part 9905-138 series 2301A Load Sharing and Speed Control. Uses a power supply of 20-40 Vdc for low voltage, a control output of 20-160 mAm, and uses a single-pole contact. | Call for Availability | |
9905-144 | Woodward model 9905-144 is part of the 2301A Load Sharing and Speed Control Series. The unit is a forward-acting, low-voltage model with a low idle speed of fifty-five percent. There is an optional SPM synchronizer connection available. | Call for Availability | |
9905-145 | Woodward part 9905-145 series 2301A Load Sharing and Speed Control. Load gain of 6 Vdc maximum at 5 A CT current, MPU clearance of 0.010-0.040 inches | Call for Availability | |
9905-146 | Woodward part 9905-146 series 2301A Load Sharing and Speed Control. CT output of 3-7 A at full load, power consumption </= 15 W nominal, MPU of 1-30 Vac. | Call for Availability | |
9905-147 | Woodward part 9905-147 series 2301A Load Sharing and Speed Control. Reverse-acting control, available in low or high-voltage models, and housed in a sheet-metal frame. | Call for Availability | |
9905-148 | Woodward model 9905-148 series 2301A Load Sharing and Speed Control. Forward-acting model, isochronous/droop mode, has a supply voltage of 20-40 VDC. | Call for Availability | |
9905-149 | Woodward part 9905-149 series 2301A Load Sharing and Speed Control. Made up of a single circuit board, and is a high-voltage forward-acting model. | Call for Availability | |
9905-150 | Woodward part 9905-150 series 2301A Load Sharing and Speed Control. Reverse-acting model operates at 20-40 VDC and must be used in an enclosed space. | Call for Availability | |
9905-151 | Woodward part 9905-151 series 2301A Load Sharing and Speed Control. Operates on a current of 0-200 mA, with a speed set input of 1-5 VDC. | Call for Availability | |
9905-194 | Woodward part 9905-194 series 2301A Load Sharing and Speed Control. Can be used with more than two prime movers, the load gain potentiometer sits at six volts. | Call for Availability | |
9905-195 | 2301A Electronic Load Sharing and Speed Control 9905-195 from Woodward Inc. This unit is a Full Authority Speed Control. | Call for Availability | |
9905-448 | Woodward model 9905-448 series 2301A Load Sharing and Speed Control. Operates at a load sensing of 90–240 Vac, and needs adequate ventilation for cooling. | Call for Availability | |
9905-794 | Woodward part 9905-794 2301A series Load Sharing and Speed Control. A low voltage model, which needs a minimum fuel contact of less than 10 mA, can be used with diesel engines. | Call for Availability | |
9907-014 | Woodward part 9907-014 series 2301A Load Sharing and Speed Control. Specifically, a speed control model, a cranking speed of 1.0 V no more than 30 Vrms. | In Stock Ships Today | |
9907-015 | Woodward part 9907-015 series 2301A Load Sharing and Speed Control. Equipped with load-sharing line relay, high/low voltage, and reverse/forward acting. | Call for Availability | |
9907-016 | Woodward part 9907-016 series 2301A Load Sharing and Speed Control. Load sharing rated load of ±5%, has nine potentiometers to control the part. | In Stock Ships 3-5 Days | |
9907-017 | Woodward part 9907-017 series 2301A Load Sharing and Speed Control. Equipped with an override of speed loss signal, identical control systems. | Call for Availability | |
9907-018 | 9907-018 is a CE-marked, low-voltage Woodward 2301A series load sharing and speed control. | In Stock Ships Today | |
9907-019 | Woodward part 9907-019 series 2301A Load Sharing and Speed Control. CE-approved, low-voltage, reverse-acting model which requires a shielded cable. | In Stock Ships 3-5 Days | |
9907-020 | Woodward part 9907-020 series 2301A Load Sharing and Speed Control. Can use a paralleling speed switch and process export/import speed control with the part. | Call for Availability | |
9907-021 | Woodward part 9907-021 series 2301A Load Sharing and Speed Control. Can be operated with steam turbines/gas engines, and operates with a proportional actuator. | Call for Availability | |
9907-023 | Woodward model 9907-023 series 2301A Load Sharing and Speed Control. Allows for individual or dual actuator installation, EU Directive compliant. | Call for Availability | |
9907-024 | Woodward model 9907-024 series 2301A Load Sharing and Speed Control. Operational with Woodward SPM-A synchronizer and an external speed trim. | Call for Availability | |
9907-236 | Woodward part 9907-236 series 2301A Load Sharing and Speed Control. Operational with diesel engines and gas turbines, typically used with dual controls. | Call for Availability | |
9907-237 | Woodward part 9907-237 series 2301A Load Sharing and Speed Control. Comes with adjustable speed linear ramps and failed speed sensor guards. | Call for Availability | |
9907-238 | Woodward part 9907-238 series 2301A Load Sharing and Speed Control. Can be operated with a battery or other alternator, and must not be secured to an engine. | Call for Availability | |
9907-239 | Woodward part 9907-239 series 2301A Load Sharing and Speed Control. Do not use near frequencies that can cause extra interference, has a vibration of 4 Gs. | Call for Availability | |
9907-250 | Woodward part 9907-250 series 2301A Load Sharing and Speed Control. Speed selection range of 500-12,000 Hz, used with split shaft/tailshaft engines. | Call for Availability | |
9907-251 | Woodward part 9907-251 series 2301A Load Sharing and Speed Control. Shock resistance of 60 Gs, and speed sensor input of 100-300 Omeg, can be used with torque converter applications. | Call for Availability |