Woodward part 9905-794 2301A series Load Sharing and Speed Control. A low voltage model, which needs a minimum fuel contact of less than 10 mA, can be used with diesel engines.

AVAILABILITY:

CALL FOR AVAILABILITY

Sell Surplus: Have a 9905-794 to sell? Sell Now
Exchange Credit: Learn more about our exchange credit program
  • Part Number: 9905-794
  • SKU: 9905794WO
  • Manufacturer: Woodward
  • Series: 2301A Electronic Load Sharing and Speed Controls

9905-794 Technical Specifications

Load Sensing Input 90-240 Vac
Load Sharing Input 0-6 Vdc
Manufacturer Woodward
Minimum Fuel Contact < 10 mA
Series 2301A
Standards CSA Certified
Voltage Model Low

About the 9905-794

Control unit 2301A series model 9905-794 is one of the many controls we offer from Woodward’s Load Sharing and Control series from our current surplus or our secondhand refurbished inventory. The 9905-794 unit is a forward-acting control operating as a low-voltage model in the range of 10-40 Vdc with an actuator current that runs at 0-20 mA. 

When operating the control with a minimum fuel contact find where the actuator current is located and asses what the current is running at, if it falls under 20-160 mA then the minimum fuel should be lesser than 10mA, for controls with an actuator current in the 40-320 mA range the minimum fuel should be lesser than 20 mA, the currents described for minimum fuel are strictly for forward-acting control models such as this one. 

The purpose of the start fuel limit potentiometer on this control is to provide a way to limit the position in which the fuel rack sits when starting engines that are of the diesel variety. When the potentiometer of the start fuel is set at the maximum actuator position that is the predominant position that it should be at, once speed control takes over the limit position is automatically disconnected. 

If during operation the prime mover does not balance at the rated no-load speed the control may be erratic, if this is the case asses the external wires on the control to establish if they have been properly shielded, the external wiring on the control could need more shielding. 

If you have any interest in this product inquiries can be directed to our sales department through phone or email. AX Control INC also offers a one to year three warranty on controls.

Reviews For 9905-794

Internal Review
(4.0)

When operating check what your actuator current is running at, the actuator current dictates what the minimum fuel contact should be at. Study your manual to assess what your minimum fuel contact should be based on the actuator current. - AX Control Tech Team

Repair Services For 9905-794

Type Lead Time Price Action
Repair Service 1-2 weeks $1289

Our highly skilled technicians can repair your 9905-794. All of our repairs come with a 3 Year AX Control Warranty. Please contact us for additional information about our repair process. To receive the repair pricing and lead time listed above please process your repair order via our website. The following repair options may be available upon request:

  • 48-72hr Rush Repair
  • Detailed Repair Reports
  • AX Control Certificate of Warranty

AX Control Warranty Info

All products we sell are backed by our unparalleled warranty. A warranty certificate will be provided with your order upon request.
All PLCs, HMIs, and Turbine Control Boards: 3 Years
All AC/DC and Servo Drives: 2 Years
All Motors: 1 Year
Learn More