T1K-08TAS

    Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures
  • 5.00 (3)
  • Click a star to rate this product
    Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures
  • 5.00 (3)
  • Click a star to rate this product
Manufactured by Automation Direct for the DirectLogic 205 series, the T1K-08TAS module is equipped with 8-point isolated comms. The model must be used with a T1K-16B or T1K-16B-1 base unit. The status indicators on this model are labeled as logic side.

AVAILABILITY:

IN STOCK
SHIPS IN 3-5 DAYS

Sell Surplus: Have a T1K-08TAS to sell? Sell Now
Exchange Credit: Learn more about our exchange credit program
  • Part Number: T1K-08TAS
  • SKU: T1K08TASAD
  • Manufacturer: Automation Direct
  • Series: DirectLogic 205

T1K-08TAS Technical Specifications

Part Number T1K-08TAS
Series DirectLogic 205 (DL205)
Manufacturer Automation Direct
Product Type 8-Point AC Output Module
Max. Inrush Current 10A for 10ms
Number of User Replaceable Fuses 8
Atmosphere No Corrosive Gases; Pollution Level 2
Base Power Requirement 300 mA at 5 VDC
Off to On Response Time < 1 ms
ON Voltage Drop 1.5 VAC @ > 50 mA, 4.0 VAC @ < 50 mA

About the T1K-08TAS

Model number T1K-08TAS is an 8 Output, 8 Common AC Powered Module module from Automation Direct. The device's 8 points are all isolated outputs. The two commons of the module are also isolated. The ambient temperature of the device should stay between 0 and 55 degrees Celsius. When the module is not in use, it should stay in a place that volleys between -20 and 70 degrees Celsius. The dimensions of the module are 3.5 x 3.15 x 3.28. It weighs 190g. The device has logic side status indicators that notify the user of fuse issues within the system.

The base power modules required to run the T1K-08TAS module are T1K-16B or T1K-16B-1  300 mA @ 5 VDC and need no external power. The off/on response of the device is less than one millisecond, and the on/off response is less than one millisecond + 1/2 cycle. 

The 8 Output, 8 Common AC Powered Module has an operating voltage range between 17-240 VAC. The AC frequency swings between 47 and 63 Hz. The maximum load current per point is two amps, while the commons have a maximum load current of 6 amps. The inrush current for the device is ten amps for ten milliseconds. The output voltage range is between 15 and 264 VAC and has a maximum leakage current of 4 mA @ 264 VAC. 

The T1K-08TAS model can be easily installed in a DIN-rail bracket in lower or upper locations. One great option about the module is that it can be easily removed from the associated bracket for easy replacement. For more information on the T1K-08TAS module, refer to the associated manuals. 

Frequently Asked Questions about T1K-08TAS

What type of module is the T1K-08TAS?

The T1K-08TAS module is an 8-point, 17/240 VAC isolated AC output module. This module is part of the DirectLogic 205 series and must be used with a T1K-16B or T1K-16B-1 base. There are eight commons per module on this unit. 

Are there any fuses on the T1K-08TAS module?

Yes, there are eight user-replaceable fuses on the T1K-08TAS model. The eight fuses are 10 A 250 V/common, with 1 point per fuse with NQ3-10 SOC Corp. 

What are the error status indicators on the T1K-08TAS model?

The T1K-08TAS module has several error status indicators; the indicators are FU3/FU4 ON indicates that fuse 3 or 4 has blown, FU5/FU6 ON indicates that fuse 5 or 6 has blown, FU1/FU2 ON indicates that fuse 1 or 2 has blown, and FU7/FU8 indicates that fuses 7 or 8 has blown. 

Reviews For T1K-08TAS

Internal Review
(5.0)

The T1K-08TAS module is excellent if needing an Automation Direct Termination module to be used in DIN-rail settings. This module will mount in a 35 mm DIN-rail system in upper or lower locations. The model can also be easily removed from the mounting system if a replacement model needs to be inserted into the system. - AX Control Tech

Repair Services For T1K-08TAS

Type Lead Time Price Action
Repair Service 1-2 weeks $262

Our highly skilled technicians can repair your T1K-08TAS. All of our repairs come with a 3 Year AX Control Warranty. Please contact us for additional information about our repair process. To receive the repair pricing and lead time listed above please process your repair order via our website. The following repair options may be available upon request:

  • 48-72hr Rush Repair
  • Detailed Repair Reports
  • AX Control Certificate of Warranty

AX Control Warranty Info

All products we sell are backed by our unparalleled warranty. A warranty certificate will be provided with your order upon request.
All PLCs, HMIs, and Turbine Control Boards: 3 Years
All AC/DC and Servo Drives: 2 Years
All Motors: 1 Year
Learn More