DS200IIBDG1AFA

    Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures
  • 5.00 (3)
  • Click a star to rate this product
    Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures
  • 5.00 (3)
  • Click a star to rate this product
This DS200IIBDG1AFA IGBT Gate Driver Board was designed and created by GE Motors & Industrial Systems, for their Mark V turbine control series.

AVAILABILITY:

CALL FOR AVAILABILITY

Sell Surplus: Have a DS200IIBDG1AFA to sell? Sell Now
Exchange Credit: Learn more about our exchange credit program
  • Part Number: DS200IIBDG1AFA
  • SKU: DS200IIBDG1AFAGBTC
  • Manufacturer: GE Boards & Turbine Control
  • Series: Mark V DS200

DS200IIBDG1AFA Technical Specifications

Part Number DS200IIBDG1AFA
Series Mark V
Manufacturer GE General Electric
Functional Acronym/Abbreviation IIBD
Product Type IIBD IGBT Driver Board
Weight Less than 2 pounds

About the DS200IIBDG1AFA

The DS200IIBDG1AFA model is an IIBD IGBT Gate Driver Board produced by General Electric as part of the Mark V DS200 series. The board will perform three primary functions. The three functions are protecting the gate drive for the power-insulated gate bipolar transistors (IGBTs), isolating incoming current feedback, and isolating the motor terminal voltage. There are circuits available in this model; six of them are optically isolated IGBT gate driver circuits, which will give one to each upper and lower IGBTs on the output phases. The other circuits available in this model are voltage, fault feedback, and current circuits for each of the output phases as well. 

Each of the faults that have been reported for the phases will be reported through the terminals on the BDCPL connector; the terminals are /FLTA, /FLTB, and /FLTC. When the IGBT on the DS200IIBDG1AFA model has been commanded to turn on, the IIBD will annunciate the faults associated with the corresponding drive circuit onto the appropriate phase fault line. Two fault types can be generated by the DS200IIBDG1AFA model; they are undervoltage and desaturation faults. When a desaturation fault has been detected during the operation of this model, the associated gate drive module will remove the gate drive to the IGBT.  

The best manual to use when installing and operating the DS200IIBDG1AFA board is the GEI-100180A IIBD IGBT Gate Driver Board Instruction Manual. It has information on the application data for the jumpers, LEDs, input/outputs, and more. 

Frequently Asked Questions about DS200IIBDG1AFA

What are the input/output connectors available on the DS200IIBDG1AFA model?

Overall there are twelve connectors. Three of the connectors are 12-pin ribbon cable connectors used in conjunction with the IGBT snubber board. One of the connectors is a thirty-four-pin ribbon cable connector used to support inputs and outputs with the IMCP board. One of the two-pin connectors is used for temperature sensing. Six of the two-pin connections are used for isolation transformer outputs. The last of the two-pin plug connectors are used for high-frequency AC inputs from the IMCP board.

How does one test this board with the power on?

When testing the board with the power on, there are strict standard practices that need to be taken when working with hazardous voltages. Make sure that you are only using instruments that are rated for high voltages present at the output of the drive. Make sure that you are not probing around the power circuit or board with high voltages present. Also, ensure that the probes being used are only insulated current probes and isolated voltage sensing. 

Reviews For DS200IIBDG1AFA

Internal Review
(5.0)

In this DS200IIBDG1AFA model circuit board from General Electric, there are nine LEDs. These LEDs will indicate the upper and lower gate drive shunt current faults and standard faults for the three output phases. Each of the LEDs has its own assigned fault which will be individually latched and annunciated. In addition to the various LED diagnostic indicators available to the DS200IIBDG1AFA, this IGBT Gate Driver Board makes use of its full possible range of product revisions, as signified by the trailing AFA digits in the alphanumeric DS200IIBDG1AFA part number. - AX Control Lead Technician

Repair Services For DS200IIBDG1AFA

Type Lead Time Price Action
Repair Service 1-2 weeks $825

Our highly skilled technicians can repair your DS200IIBDG1AFA. All of our repairs come with a 3 Year AX Control Warranty. Please contact us for additional information about our repair process. To receive the repair pricing and lead time listed above please process your repair order via our website. The following repair options may be available upon request:

  • 48-72hr Rush Repair
  • Detailed Repair Reports
  • AX Control Certificate of Warranty

AX Control Warranty Info

All products we sell are backed by our unparalleled warranty. A warranty certificate will be provided with your order upon request.
All PLCs, HMIs, and Turbine Control Boards: 3 Years
All AC/DC and Servo Drives: 2 Years
All Motors: 1 Year