The DS200SHVMG1ACD SCR High Voltage Interface Card was manufactured by General Electric for the Mark V Series of turbine control systems.

AVAILABILITY:

CALL FOR AVAILABILITY

Sell Surplus: Have a DS200SHVMG1ACD to sell? Sell Now
Exchange Credit: Learn more about our exchange credit program
  • Part Number: DS200SHVMG1ACD
  • SKU: DS200SHVMG1ACDGBTC
  • Manufacturer: GE Boards & Turbine Control
  • Series: Mark V DS200

DS200SHVMG1ACD Technical Specifications

Manufacturer GE General Electric
Series Mark V
Part Number DS200SHVMG1ACD
Functional Description SCR High Voltage M-Frame Interface Board
Instruction Manual GEI-100174
Functional Acronym SHVM
PCB Coating Normal Coating
Functional Revision 1 A
Functional Revision 2 C
Artwork Revision D

About the DS200SHVMG1ACD

The DS200SHVMG1ACD is a high voltage M-frame interface board. Since it was developed for the General Electric Mark V board series, this card can be used across a wide range of GE brand exciters and drives. The Mark V Series that this DS200SHVMG1ACD PCB belongs to, however, is classified as a legacy series as it has been discontinued for production by its original manufacturer. While the Mark V Series that this DS200SHVMG1ACD printed circuit board has been attributed to may exist as a General Electric legacy series, it is additionally considered one of the later General Electric product series offering their patented Speedtronic assembly. This DS200SHVMG1ACD PCB's Mark V Series is truly the Mark V Turbine Control System Series, as it has specific applications in wind, gas, and steam turbine control and management systems. This DS200SHVMG1ACD High Voltage M-frame Interface Board is not the original product with its intended functionality to exist within the Mark V Turbine Control System Series; that would be the DS200SHVMG1 High Voltage M-frame Interface Board missing this DS200SHVMG1ACD product's three significant revisions. Interfacing between the M-frame drive’s SCR bridge and the DCFB/SDCI power supply board and the PCCA power connect card is provided with this board.

Hardware Tips and Specifications

DS200SHVMG1ACD provides an array of drive functions to the Mark V Series automated drive when installed. The board works to convert shunt signals (between -500 and 500 mV) into differential frequency outputs (0 to 500 kHz). The conversion of the shunt signals into frequencies occurs in the positive and negative DC voltage controlled oscillator (VCO) circuits. When the conversions are complete, the frequency signals are then sent to either the DCFB or SDCI board or the PCCA card. A 10:1 current transformer attenuation is is available for the AC line currents. The DS200SHVMG1ACD High Voltage M-frame Interface board can accommodate most attenuation requirements using the 17 integrated configurable jumpers, which are manually moveable on its external assembly. These seventeen jumpers and their specific DS200SHVMG1ACD board applications are described in detail in the instructional manual attached in the manuals tab above. Several different styles of relevant Mark V Series connectors are additionally present in the assembly of this DS200SHVMG1ACD High Voltage M-frame Interface Board, each of which also accompanied by their own factory-printed reference designator label. Some of these varying connectors include:

  • The CT1PL L1 ACCT current input Connector
  • The CT3PL L3 ACCT current input Connector
  • The DC1PL Shunt 1 Connector
  • The DC2PL Shunt 2 Connector
  • The 1CPL L1 ACCT current output Connector
  • The SQPL 25 kHz power Connector
  • The IA1PL DC1 shunt differential VCO positive output Connector
  • The IA2PL DC1 shunt differential VCO negative output Connector

All of these various connector types have been named by a combination of their factory-printed designator labellings and their function to the DS200SHVMG1ACD High Voltage M-frame Interface Board and greater Mark V Series automated drive assembly. Connections made to the base circuit board of this DS200SHVMG1ACD product should be well-protected by this DS200SHVMG1ACD PCB's normal style of PCB protective coating, which is discoverable upon a diligent breakdown of this DS200SHVMG1ACD PCB's DS200SHVMG1ACD functional product number. Some other valuable hardware details retrievable from this product number include the DS200SHVMG1ACD PCB's domestic location of original manufacture, SHVM functional product abbreviation, group one Mark V Series grouping, and its full, three-fold revision history. 

Frequently Asked Questions about DS200SHVMG1ACD

What's the difference between safety signals "warning" and "caution" on a GE DS200SHVMG1ACD?
"Warning" is the safety signal that is more detrimental on DS200SHVMG1ACD. When "warning" is seen on DS200SHVMG1ACD, it indicates a procedure, practice, condition, or statement on DS200SHVMG1ACD that could result in personal injury or death if not strictly observed. "Caution" for DS200SHVMG1ACD is DS200SHVMG1ACD's safety signal that could result in damage to or destruction of DS200SHVMG1ACD equipment.
What type of transformers does DS200SHVMG1ACD use?
DS200SHVMG1ACD uses hardware jumper-selectable 10:1 current transformers to provide additional current attenuation capability. DS200SHVMG1ACD doesn't always use transformers, but DS200SHVMG1ACD uses transformers for the AC line currents when attentuation is required, which is when DS200SHVMG1ACD is above 144 mA main line ACCT secondary current.
Where can I find information about the connectors on DS200SHVMG1ACD?
DS200SHVMG1ACD has 8 plug connectors and DS200SHVMG1ACD has 18 stab connectors. Tables 2-9 in the DS200SHVMG1ACD manual, Manual GEI-100174, show the pin signals of each of DS200SHVMG1ACD's plug connectors. Table 10 in the manual provides descriptions for stab connectors on DS200SHVMG1ACD. Figure 1 in the manual for DS200SHVMG1ACD also displays a layout of DS200SHVMG1ACD, showing the locations of the connectors on DS200SHVMG1ACD.
What will I find in the manual for DS200SHVMG1ACD?
In the manual for DS200SHVMG1ACD, Manual GEI-100174, you will find information on DS200SHVMG1ACD and other SHVM boards. The manual is the SCR High Voltage M-Frame Interface Board Manual and the contents in the manual include: safety symbol legend, functional description of DS200SHVMG1ACD, application data for DS200SHVMG1ACD, and renewal.warranty replacement for DS200SHVMG1ACD.

Reviews For DS200SHVMG1ACD

Internal Review
(5.0)

This DS200SHVMG1ACD High Voltage M-frame Interface Board is a valuable member of its greater Mark V Turbine Control System Series, as evidenced by its full revision history with two functionality-boosting functional revisions. This well-documented General Electric product offering is a highly-customizable interfacing option, as it features seventeen selectable hardware jumpers in its assembly, with applications described in the attached instructional manual. This DS200SHVMG1ACD PCB is available today, for both repair and replacement. - AX Control Lead Technician

Repair Services For DS200SHVMG1ACD

Type Lead Time Price Action
Repair Service 1-2 weeks $350

Our highly skilled technicians can repair your DS200SHVMG1ACD. All of our repairs come with a 3 Year AX Control Warranty. Please contact us for additional information about our repair process. To receive the repair pricing and lead time listed above please process your repair order via our website. The following repair options may be available upon request:

  • 48-72hr Rush Repair
  • Detailed Repair Reports
  • AX Control Certificate of Warranty

AX Control Warranty Info

All products we sell are backed by our unparalleled warranty. A warranty certificate will be provided with your order upon request.
All PLCs, HMIs, and Turbine Control Boards: 3 Years
All AC/DC and Servo Drives: 2 Years
All Motors: 1 Year
Learn More

DS200SHVMG1ACD Manuals, White Papers, Data Sheets, and Troubleshooting