DS200TCTLG1A

    Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures
  • 4.86 (14)
  • Click a star to rate this product
    Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures
  • 4.86 (14)
  • Click a star to rate this product
The DS200TCTLG1A Steam Turbine Reheat Board was manufactured by General Electric for the Mark V Series of turbine control systems.

AVAILABILITY:

CALL FOR AVAILABILITY

Sell Surplus: Have a DS200TCTLG1A to sell? Sell Now
Exchange Credit: Learn more about our exchange credit program
  • Part Number: DS200TCTLG1A
  • SKU: DS200TCTLG1AGBTC
  • Manufacturer: GE Boards & Turbine Control
  • Series: Mark V DS200

DS200TCTLG1A Technical Specifications

OEM GE General Electric
Product Series Mark V
Functional Part Number DS200TCTLG1A
Functional Description ST TMR Large Reheat Board
Functional Acronym TCTL
PCB Coating Style Normal Coating
1st Functional Revision A

About the DS200TCTLG1A

The DS200TCTLG1A is a Steam Turbine Trip Board, otherwise known as a Steam Turbine Reheat Board, that was initially created by General Electric. This board is a legacy series and may now be a little hard to find due to this legacy status, as it is no longer in active production by the original GE manufacturer. This DS200TCTLG1A Steam Turbine Reheat Board's Mark V Series, while existing as a legacy series, is considered to be one of the final General Electric Mark product series to feature the patented Speedtronic control system technology in its products, which comes in handy for this DS200TCTLG1A PCB's specified applications in the control and management systems of steam, wind, and gas turbine automated drive assemblies. This DS200TCTLG1A Steam Turbine Reheat Board alters the original DS200TCTLG1 parent Steam Turbine Reheat Board through its attachment of a singular, A-rated functional product revision.

Hardware Tips and Specifications

The DS200TCTLG1A is also known as a turbine trip circuit, and is populated by its own series of hardware components and component specifications to gain its specific Mark V Turbine Control System Series functionality. This DS200TCTLG1A board is a part of the master trip circuit and the protection core within its greater Mark V Series automated drive assembly. This circuit has at least two sets of primary trip relays (PTR1 & 2) and then three sets of three emergency trip relays (ETR1 & 2); the PTRs are typically controlled by other boards like the TCQA while the ETRs are controlled by TCEA boards. If there becomes an issue with two of the three relays in this system, it will cause the turbine to trip.

The DS200TCTLG1A also has other features than the trip relays. It possesses four auxiliary control outputs that include an oil test solenoid, a mechanical lockout solenoid, an oil reset solenoid valve, and an electrical lockout solenoid. The DS200TCTLG1A can be used to perform the actual electrical overspeed trip test, the mechanical trip piston test, the actual mechanical overspeed trip test, the TMR cross trip test, the electrical overspeed trip test (online), the electrical trip test,  the electrical overspeed trip test (offline), and the emergency over speed cross trip test. For more information about the DS200TCTLG1A, please consult the GE Application Manual GEH-6195D, which may be limited in its online availability due to this DS200TCTLG1A product's Mark V Series' status as a now-obsolete General Electric legacy series. Before making a final purchase decision on this DS200TCTLG1A Steam Turbine Reheat Board, it is important to understand that this DS200TCTLG1A product's A-rated functional product revision almost certainly alters its originally-introduced performance specifications and dimensions from their original base-revised state. The assembly of this DS200TCTLG1A Steam Turbine Reheat Board should be well-protected beneath a layer of normal-style PCB protective coating, which is chemically-applied to the base circuit board of this DS200TCTLG1A model and envelops and protects individual hardware elements in a thick rudimentary protective coat based on functional priority to the DS200TCTLG1A board and its greater automated drive.

Frequently Asked Questions about DS200TCTLG1A

What type of turbine does DS200TCTLG1A have?
DS200TCTLG1A is a steam turbine trip board. DS200TCTLG1A does not use gas turbine.

Would this DS200TCTLG1A printed circuit board be protected by any sort of warranty following my original purchase?

Yes. Immediately upon your original purchase from AX Control, this DS200TCTLG1A printed circuit board would be deemed as protected by our guaranteed three-year circuit board warranty.

Reviews For DS200TCTLG1A

Internal Review
(5.0)

This DS200TCTLG1A printed circuit board offers several conflicting functional descriptions in its original Mark V Turbine Control System Series instructional manual materials, from that of a Steam Turbine Reheat Board to that of a Steam Turbine Trip Board. The normal assembly status and singular A-rated functional revision of this DS200TCTLG1A PCB are not debatable, however, as they are embedded in the DS200TCTLG1A functional product number. - AX Control Lead Technician

Repair Services For DS200TCTLG1A

Type Lead Time Price Action
Repair Service 1-2 weeks $812

Our highly skilled technicians can repair your DS200TCTLG1A. All of our repairs come with a 3 Year AX Control Warranty. Please contact us for additional information about our repair process. To receive the repair pricing and lead time listed above please process your repair order via our website. The following repair options may be available upon request:

  • 48-72hr Rush Repair
  • Detailed Repair Reports
  • AX Control Certificate of Warranty

AX Control Warranty Info

All products we sell are backed by our unparalleled warranty. A warranty certificate will be provided with your order upon request.
All PLCs, HMIs, and Turbine Control Boards: 3 Years
All AC/DC and Servo Drives: 2 Years
All Motors: 1 Year
Learn More