General Electric 500V DC300 25HP 41 Amps Adjustable Speed Drive.

AVAILABILITY:

CALL FOR AVAILABILITY

Sell Surplus: Have a 7VXLD533CD01 to sell? Sell Now
Exchange Credit: Learn more about our exchange credit program
  • Part Number: 7VXLD533CD01
  • SKU: 7VXLD533CD01GD
  • Manufacturer: GE Drives
  • Series: DC300 Drives

Frequently Asked Questions about 7VXLD533CD01

What does the diagnostic readout 010101 mean?

The diagnostic readout 010101 has a fault number FL85 and a fault name A5FSH and means the SCR A5F or A2R is shorted (L, T).  -A High current test may be enabled - run a low current test. -Check for shorted out SCR and replace them.

What does the diagnostic readout 010110 mean?

The diagnostic readout 010110 has a fault number FL86 and a fault name A6FSH which means the SCR A6F or A3R is shorted (L, T). -The High current test may be enabled - run a low current test. -Check for a shorted SCR and replace. 

What does the diagnostic readout 011111 mean?

The diagnostic readout 011111 has a fault number FL95 and a fault name WATCH and means FUP watchdog has detected RUP has misoperated (L, T). -See FL58  -FL58  means the U4 is not communicating correctly with the U5.  -Check for PROM revision compatibility -Digital tach pulse rate exceeds 41,000 Hertz. -Noise on the tach input. .  

What does the diagnostic readout 100000 mean?

The diagnostic readout 100000 has no fault number and a fault name PASSEDand means the annunciates when SCR test has passed. NOTE that this is not a fault condition.

What does the diagnostic readout 100001 mean?

The diagnostic readout 100001 has a fault number FL97 and a fault name OCTFL and means the SCR open circuit test failed (L, T). -A low current test may be enabled - run a high current test. -The FU4-DC fuse is open (regenerative drive only).  -The Armature circuit is open. -Brushes are missing or are disconnected. -The 5PL is disconnected or damaged. -The Main contactor is not picking up. -Loss of current feedback - check 1PL-20 and DRPL.  -The P2-CFB ZERO on Power Supply card is misadjusted. 

Repair Services For 7VXLD533CD01

Type Lead Time Price Action
Repair Service 1-2 weeks $877

Our highly skilled technicians can repair your 7VXLD533CD01. All of our repairs come with a 3 Year AX Control Warranty. Please contact us for additional information about our repair process. To receive the repair pricing and lead time listed above please process your repair order via our website. The following repair options may be available upon request:

  • 48-72hr Rush Repair
  • Detailed Repair Reports
  • AX Control Certificate of Warranty

AX Control Warranty Info

All products we sell are backed by our unparalleled warranty. A warranty certificate will be provided with your order upon request.
All PLCs, HMIs, and Turbine Control Boards: 3 Years
All AC/DC and Servo Drives: 2 Years
All Motors: 1 Year
Learn More

7VXLD533CD01 Manuals, White Papers, Data Sheets, and Troubleshooting