269-10C-125VDC

    Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures
  • 4.00 (1)
  • Click a star to rate this product
    Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures
  • 4.00 (1)
  • Click a star to rate this product
Motor Management Relay 269-10C-125VDC Multilin General Electric 269 Digital Relay

AVAILABILITY:

IN STOCK
SHIPS TODAY

Sell Surplus: Have a 269-10C-125VDC to sell? Sell Now
Exchange Credit: Learn more about our exchange credit program
  • Part Number: 269-10C-125VDC
  • SKU: 26910C125VDCGM
  • Manufacturer: GE Multilin
  • Series: 269 Motor Management Relay

About the 269-10C-125VDC

The 269-10C-125VDC is a Multilin motor management relay from GE. The 269-10C-125-VDC has been designed for the protection and control of medium-sized AC motors. Some key benefits to the 269-10-125VDC include enhanced thermal modeling, temperature monitoring with programmable RTD inputs, built-in simulation features, and field-upgradeable settings.

The 269-10C-125VDC comes with these standard features:

  • data logging

  • learned and statistical data applications

  • programmable RTDs

  • 4 output relays

  • ground fault

  • 2 auxiliary relays

  • ground fault

  • latched main trip relay

  • locked rotor

Outputs on the 269-10C-125VDC have the following voltage ratings: DC resistive 10A (make/carry continuous voltage) 30A (make/carry 0.2 sec) 0.5A break. DC inductive (L/r=7 ms) 10A (make/carry continuous voltage) 30A (make/carry 0.2 sec) 0.25A break. Maximum power consumption is 20VA Holdup is 100ms (@ 120VAC/125 VDC.)

The 269-10C-125VDC is designed with a compact plastic and metal housing. The front panel has a keypad, a 48 character LCD display, four LED indicators for outputs (trip, alarm, Aux. 1 and Aux. 2) and one LED indicator for self-test diagnostics. The exterior case is flame retardant and resistant to corrosion. The user should follow all manufacturer recommendations for installation, including recommendations to avoid strong magnetic field interference.

Operating temperature of the 269-10C-125-VDC ranges between -25 degrees Celsius to +60 degrees Celsius at up to 95% non-condensing humidity. The 269-10C-125VDC can operate at altitudes up to 2000 meters. Its pollution degree is 2. ISO rated. UL listed. Conforms to IEC 947-1, 1010-1. Conforms to EN55011/CISPR11, EN50082-2.

Frequently Asked Questions about 269-10C-125VDC

What are the keypad characteristics of the 269-10C-125VDC General Electric motor management digital Multilin relay?
The 269-10C-125VDC has a four by three button keypad on the front view of the relay case. This keypad is located below the five status indicators and service LEDs. The user is able to choose between actual values, alarm causes, diagnosis, trip causes, or various set points using the key pad. The rear view of the 269-10C-125VDC motor management relay shows the top right control power location. Depending on if the 269 relay is a high (HI) or low (LO) control power, this range varies between individual 269 Multilin relays. To the left of the control power at the top of the unit, there are four output relays. Below these programmable conditions are found RTDs 7-10.
What are RTDs 1-6 used for in the 269-10C-125VDC motor management Multilin GE relay?
The RTDs 1-3 and 4-6 are generally used for protection against stator winding as specified in the manuel.
What are the input/output features of the 269-10C-125VDC motor management Multilin GE relay located on the right aspect of the rear view?
The right aspect of the rear side for the 269 Multilin relay shows various inputs and outputs. The various inputs and outputs of this relay are a spare input, MPM com port, differential relay input, access input, external reset, analog output, emergency restart, and many other input/output capabili

Reviews For 269-10C-125VDC

Internal Review
(4.0)

This GE Multilin 269 Motor Management Relay offers a keypad and display on its front panel. This allows for reading or resetting alarms locally. This can also occur through remote connections to external devices. Read through associated manuals for more information.

Repair Services For 269-10C-125VDC

Type Lead Time Price Action
Repair Service 1-2 weeks $1207

Our highly skilled technicians can repair your 269-10C-125VDC. All of our repairs come with a 3 Year AX Control Warranty. Please contact us for additional information about our repair process. To receive the repair pricing and lead time listed above please process your repair order via our website. The following repair options may be available upon request:

  • 48-72hr Rush Repair
  • Detailed Repair Reports
  • AX Control Certificate of Warranty

AX Control Warranty Info

All products we sell are backed by our unparalleled warranty. A warranty certificate will be provided with your order upon request.
All PLCs, HMIs, and Turbine Control Boards: 3 Years
All AC/DC and Servo Drives: 2 Years
All Motors: 1 Year
Learn More