The 350-E-P1-G1-H-E-S-C-M-3E-D-H Protection System is a model that does not have any programmable LEDs. The language on this device is English. This protection system can be used in harsh environments due to its conformal coating.

AVAILABILITY:

IN STOCK
SHIPS IN 3-5 DAYS

Sell Surplus: Have a 350-E-P1-G1-H-E-S-C-M-3E-D-H to sell? Sell Now
Exchange Credit: Learn more about our exchange credit program
  • Part Number: 350-E-P1-G1-H-E-S-C-M-3E-D-H
  • SKU: 350EP1G1HESCM3EDHGM
  • Manufacturer: GE Multilin
  • Series: 350 Feeder Protection System

350-E-P1-G1-H-E-S-C-M-3E-D-H Technical Specifications

67P ANSI Device Description Phase Directional Element
Breaker Control Function Opens/Closes the Feeder Breaker
Clock Setup Date and Time
Gross Weight 11 lbs. or 5 kg
Ingress Protection IP40 Front , IP10 back, IP20 cover (optional)
Model Type Feeder Protection System with Drawout Case
Overfrequency Level Accuracy ±0.03 Hz
Settings Password 3-10 Alphanumeric Characters for Remote and Local Access
Transient Recorder Buffer Size 3 s

Product Description

According to the order code breakdown for the 350-E-P1-G1-H-E-S-C-M-3E-D-H Feeder Protection System in the corresponding GE Multilin System Production Guide, this specific model has a one-ampere three-phase current input with a ground current of one ampere, which is denoted by the P1 and G1 codes. While this model is a drawout version and a language option is available for drawout case models, this model does not have programmable LEDs. According to the H at the end of the catalog number, there is a harsh environmental conformal coating.

One feature that the 350-E-P1-G1-H-E-S-C-M-3E-D-H system also has is its different password protection systems. There are three password types a reset password, a control password, and a settings password. The control and settings password are the same with a password of three to ten alphanumeric characters for both remote and local access. The master reset password has a higher number of alphanumeric characters which is eight to ten characters. 

There are communication ports used with this model. According to the 3E code, the communications are an Ethernet and Standard with IEC 61850 and IEC 60870-5-104 protocols, and a Modbus TCP/IP feature. 

During the operation of the 350-E-P1-G1-H-E-S-C-M-3E-D-H model if the user wishes to access the measured values, fault analysis information, and status of digital inputs and outputs it will be done through the Actual Values mode. The messages will be organized into several different logical groups for easy reference. All of the potential messages, values, and references can be found in chapter four of the Multilin System Production Guide which is attached to this page in the manuals tab. 

Frequently Asked Questions about 350-E-P1-G1-H-E-S-C-M-3E-D-H

What are the applications for a 350-E-P1-G1-H-E-S-C-M-3E-D-H Multilin GE feeder protection device?
The 350-E-P1-G1-H-E-S-C-M-3E-D-H Multilin GE feeder protection device is a member of the 350 Multilin series with a variety of feeder protection applications. These devices can provide primary control and protection for feeders that are either cable feeders or industrial overhead feeders. The feeders can be medium or high voltage distribution feeders. The 350-E-P1-G1-H-E-S-C-M-3E-D-H Multilin GE feeder protection device will also provide protection to small and medium distribution transformers in addition to back-up protection for HV applications. These 350 feeder protection devices have capacitor bank protection as well. The 350-E-P1-G1-H-E-S-C-M-3E-D-H Multilin GE feeder protection device comes with various control applications (Multi-shot recloser, multiple setting groups, Cold Load Pickup, etc.).
Does the 350-E-P1-G1-H-E-S-C-M-3E-D-H Multilin GE have basic protection functions unique to the 350 Multilin series?
The 350-E-P1-G1-H-E-S-C-M-3E-D-H Multilin, and other members of the 350 Multilin series have a basic function that incorporates ground, multiple phase, and neutral time and overcurrent elements in order to coordinate upstream and downstream units to allow for protection of the unit. The 350 Multilin affords cold load pick up blocking, synchrocheck, and autoreclose in addition to other important feeder breaker control characteristics. The unit also has breaker failure control features.

Reviews For 350-E-P1-G1-H-E-S-C-M-3E-D-H

Internal Review
(4.0)

One downside of owning the 350-E-P1-G1-H-E-S-C-M-3E-D-H is the case. Sometimes the case will break which will not cause issues during operation but it can potentially cause potential damage to the keypad. - AX Control Tech Team

  • 350-EP1G1HESCM3EDH

Repair Services For 350-E-P1-G1-H-E-S-C-M-3E-D-H

Type Lead Time Price Action
Repair Service 1-2 weeks $1490

Our highly skilled technicians can repair your 350-E-P1-G1-H-E-S-C-M-3E-D-H. All of our repairs come with a 3 Year AX Control Warranty. Please contact us for additional information about our repair process. To receive the repair pricing and lead time listed above please process your repair order via our website. The following repair options may be available upon request:

  • 48-72hr Rush Repair
  • Detailed Repair Reports
  • AX Control Certificate of Warranty

AX Control Warranty Info

All products we sell are backed by our unparalleled warranty. A warranty certificate will be provided with your order upon request.
All PLCs, HMIs, and Turbine Control Boards: 3 Years
All AC/DC and Servo Drives: 2 Years
All Motors: 1 Year
Learn More