The SR469-P5-LO-A20, like other relays in the SR469 family, is designed with protection against ground faults. This occurs through two dedicated ground current inputs. Additionally, the unit offers frequency and voltage protection, as well as load loss detection.

AVAILABILITY:

IN STOCK
SHIPS IN 3-5 DAYS

Sell Surplus: Have a SR469-P5-LO-A20 to sell? Sell Now
Exchange Credit: Learn more about our exchange credit program
  • Part Number: SR469-P5-LO-A20
  • SKU: SR469P5LOA20GM
  • Manufacturer: GE Multilin
  • Series: 469 Motor Management Relay

SR469-P5-LO-A20 Technical Specifications

Operation Time without Supply Voltage 30 ms
Analog Current Input Accuracy ±1% of full scale
Typical Power Supply 25 VA
Voltage Type Low
Analog Outputs 4-20 mA
Phase CT Secondaries 5A Phase
Power Supply 20 to 60 VDC

About the SR469-P5-LO-A20

As part of the SR469 GE Multilin relay family, the SR469-P5-LO-A20 is designed to offer complete protection and management of medium to large motors.   This is only one of many versions of the SR469 available within our inventory.  If this particular unit doesn’t suit, look at our inventory of other units available. 

The SR469-P5-LO-A20 is a basic SR469 unit with five Amp phase CT secondaries.  The unit has low control power (24-60 VDC, 20-48 VAC @ 48-62 Hz).   It offers 4-20 mA analog outputs.   This unit is not recommended for harsh environments.  If you need a unit for harsh environmental use, please look for a unit that ends in -H. 

The SR469-P5-LO-A20, like other relays in the SR469 family, is designed with protection against ground faults.  This occurs through two dedicated ground current inputs.  Additionally, the unit offers frequency and voltage protection, as well as load loss detection.  It also has current unbalance, reverse active power, and overtorque.  Overtorque will protect a driven load from mechanical failure and breakage. 

Other standard features of the SR469-P5-LO-A20 include speed counter alarm and trip functions, trip coil supervision, reduced voltage starting supervision, and two-speed motor protection.  The unit has four configurable analog inputs that can be used to measure motor operation.  Additionally, the unit has six Form-C output relays.  Four of these are non-failsafe.  

Use GE Multilin manuals for more information regarding installation, handling, and safety.  We recommend reading through manuals and user guides before unboxing your part from AX Control.  This ensures your safety as well as the longevity of your new equipment. 
 

Frequently Asked Questions about SR469-P5-LO-A20

How to properly monitor the temperature of this SR469-P5-LO-A20 motor management relay GE?
There are twelve programmable field resistance temperature detectors that are used to monitor the temperatures of this 
SR469-P5-LO-A20 relay. The settings can be changed for the resistance temperature detectors in the S8 resistance temperature detection temperture page in the settings. The resistance temperature detectors can be set to Alarm and Trip outputs and also be measured by the comparison of the pick up values in the resistance temperature detectors. To properly monitor the temperatures of the relay, the resistance temperature detection types need to be changed in the S8 resistance temperature detection temperature settings page. The types that need to be set at "100 Ohm Platinum" are the Stator Resistance Temperature Detector type, Bearing Resistance Temperature Detection type, Ambient Resistance Temperature Detecter type, and Other Resistances Temperatures Detecters types. Other settings for the Stator Over temperature protection can be found in the manual with this part number 1601-0122-A9.
Are there any additional settings that will need to be made to the settings of the SR469-P5-LO-A20 GE motor management relay?
There are some cases where the GE Motor Management Relay will need additional setting changes for the motor applications to function properly and record parameters like the voltage levels of the relay. For example the settings for the pick up could be set at 70 percent for the nominal Voltage when the relay is started, then the pick up could be set to 80 percent for the nominal Voltage with the relay is actually running, and the time delay can be set to 13.0 seconds. This function can only be active if there still is voltage in the feeding line, more information on this under voltage protection can be found in the manual.

Reviews For SR469-P5-LO-A20

Internal Review
(4.0)

While the SR469-P5-LO-A20 is an excellent model in the 469 series, it does not contain many of the optional features such as Ethernet, enhanced faceplate, or conformal coating. Prospective buyers should ensure no additional features are required before purchasing this particular unit. -AX Control Technicians

Repair Services For SR469-P5-LO-A20

Type Lead Time Price Action
Repair Service 1-2 weeks $1936

Our highly skilled technicians can repair your SR469-P5-LO-A20. All of our repairs come with a 3 Year AX Control Warranty. Please contact us for additional information about our repair process. To receive the repair pricing and lead time listed above please process your repair order via our website. The following repair options may be available upon request:

  • 48-72hr Rush Repair
  • Detailed Repair Reports
  • AX Control Certificate of Warranty

AX Control Warranty Info

All products we sell are backed by our unparalleled warranty. A warranty certificate will be provided with your order upon request.
All PLCs, HMIs, and Turbine Control Boards: 3 Years
All AC/DC and Servo Drives: 2 Years
All Motors: 1 Year