489-P1-LO-A20

    Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures
  • 4.50 (4)
  • Click a star to rate this product
    Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures
  • 4.50 (4)
  • Click a star to rate this product
The Generator Management Relay 489-P1-LO-A20 is a model that operates on a low control power at 20 to 60 vDC or 20 to 48 VAC at 48-62 Hz. This model has an analog output of four to twenty milliamperes.

AVAILABILITY:

CALL FOR AVAILABILITY

Sell Surplus: Have a 489-P1-LO-A20 to sell? Sell Now
Exchange Credit: Learn more about our exchange credit program
  • Part Number: 489-P1-LO-A20
  • SKU: 489P1LOA20GM
  • Manufacturer: GE Multilin
  • Series: 489 Generator Management Relay

489-P1-LO-A20 Technical Specifications

Communication Ports Protocol Modbus® RTU / half duplex, DNP 3.0
Current Rating Fuse 2.5 A
Demand Metering Update Rate 1 Minute
Digital Inputs 9 Opto-Isolated Inputs
Ground Directional Elements Alarm and Trip
Negative Sequence Overcurrent Pickup Level 3 to 100% FLA in steps of 1
Phase Voltage Inputs Burden > 500 KΩ

About the 489-P1-LO-A20

489-P1-LO-A20 is a Multilin 489 generator management relay that is manufactured by GE Multilin. This generator relay has 1 A phase CT secondaries. The LO control power is 20-60 VDC and 20-48 VAC at 48-62 Hz. The analog outputs on this relay are 4 to 20 mA. This relay has a basic display. This generator management relay does not have a protective conformal coating to protect against chemical environments. If you have any questions about this part, please contact AX Control.

The trip protection features on the relay include electrical lockout analog inputs 1 to 4, thermal overload, RTDs (stator, bearing, ambient, other), low forward power, reverse power for anti-motoring, reactive power (kvar) for loss of field, distance element (2 zones of protection), loss of excitation (2 impedance circles), neutral Undervoltage (3rd harmonic), neutral overvoltage (fundamental), over frequency (two-step), under frequency (two-step), high-set phase overcurrent, ground directional, percentage phase differential, ground overcurrent, negative-sequence overcurrent, phase overcurrent with voltage restraint, inadvertent energization, offline overcurrent protection during startup, and seven assignable digital inputs.

The alarm protection features on the relay include IRIG-B failure, service (self-test failure), analog inputs 1 to 4, generator running hours, demand (current MW, Mvar, MVA), VT fuse failure, trip counter, thermal overload, open RTD, short/low RTD, RTD (stator, bearing, ambient, other), low forward power, reverse power, reactive power (kvar), neutral Undervoltage (3rd harmonic), neutral overvoltage (fundamental), over frequency, under frequency, volts per hertz, overvoltage, Undervoltage, ground directional, ground overcurrent, negative sequence, overload, and 7 assignable digital inputs (general input and tachometer).

Frequently Asked Questions about 489-P1-LO-A20

What does the LO stand for in the part number 489-P1-LO_A20 GE Multilin 489 Generator Management Relay?
The LO stands for low control power in the part number 489-P1-LO-A20 for the GE Multilin generator management relay. The low control power for the GE Multilin generator management relay consists of 20 to 60 V DC; 20 to 48 V AC at 48 to 62 Hz.
How many output relays for the 489-P1-LO-A20 GE Multilin Generator Management Relay?
The GE Multilin 489-P1-LO-A20 has six Form-C output relays, five are always non-failsafe and the sixth Service relay always failsafe. The 6th Service relay, as the failsafe relay, will be energized as normal, it will also de-energize when ready to operate.
How many voltage transformer inputs does a 489-P1-LO-A20 have and how many are for neutal voltage?
The GE Multilin Generator Management Relay 489-P1-LO-A20 has four voltage transformer inputs. Three of the four voltage transformer inputs are for generator terminal voltage and one is for neutral voltage.
Are there any internal ground connections on the CT inputs on the 489-P1-LO-A20?
The 489-P1-LO-A20  does not have any internal ground connections on the CT inputs. If the unit is withdrawn, the automatic mechanisms short eash phase CT circuit.

Reviews For 489-P1-LO-A20

Internal Review
(5.0)

Digital Inputs are available on the 489-P1-LO-A20 relay. The inputs are only used for dry contacts with two of the inputs being used for breaker and access status. - AX Control Tech Team

Repair Services For 489-P1-LO-A20

Type Lead Time Price Action
Repair Service 1-2 weeks $1449

Our highly skilled technicians can repair your 489-P1-LO-A20. All of our repairs come with a 3 Year AX Control Warranty. Please contact us for additional information about our repair process. To receive the repair pricing and lead time listed above please process your repair order via our website. The following repair options may be available upon request:

  • 48-72hr Rush Repair
  • Detailed Repair Reports
  • AX Control Certificate of Warranty

AX Control Warranty Info

All products we sell are backed by our unparalleled warranty. A warranty certificate will be provided with your order upon request.
All PLCs, HMIs, and Turbine Control Boards: 3 Years
All AC/DC and Servo Drives: 2 Years
All Motors: 1 Year
Learn More