  • Part Number: 760-P1-G1-S1-LO-A10-R
  • SKU: 760P1G1S1LOA10RGM
  • Manufacturer: GE Multilin
  • Series: 750/760 Feeder Management Relay

760-P1-G1-S1-LO-A10-R Technical Specifications

Ambient Storage Temperature Range -40°C (-40°F) to +80°C (176°F)
Analog Input Conversion Range 0 to 21 mA
Features Simulation Function, Drawout Construction
Manual 1601-0120-AE
Operating Temperature Range -40°C (-40°F) to +60°C (140°F)
Relay Dimensions 7” W, 6.5” L, 8.5” H
Weight 7.9kg

About the 760-P1-G1-S1-LO-A10-R

Equipped with red breaker closed LEDs, General Electric Multilin’s 760-P1-G1-S1-LO-A10-R is perfect for protecting and managing feeder distribution systems. This particular model is a low control power model and equipped with red breaker LEDs. The relay is housed in a standard SR 760 series chassis, which offers a locking mechanism, defense against particulates, and a drawout construction that protects the relay during system functions.

One of the major benefits of the 760-P1-G1-S1-LO-A10-R is its highly configurable nature; both the wiring and setpoint systems can be specified for each unique system. The 1601-0120-AE can provide users with some basic guidelines for typical wiring setups, but diagnostics such as data logging and oscillography can also give users information to better configure their system as time goes on. For example, system trips are triggered when values exceed intervals for a user-specified time, allowing users to increase or decrease the sensitivity with which a trip will occur. 

Some users question the difference between GE Multilin’s 750 series and GE Multilin’s 760 series, especially because they are contained within the same manual. The parts have a few distinct differences, primarily because the 760 possesses the recloser feature while the 750 series does not. The reclosure feature is initiated as a form of overcurrent protection or can be manually initiated by the user; users can program up to four reclosure operations. The recloser is able to open the line for protection and close it once again when conditions are safe. It can also keep it open in the event that the problem does not resolve itself.

Frequently Asked Questions about 760-P1-G1-S1-LO-A10-R

What is delta voltage transformers are used with the GE Feeder Management Relay 760-P1-G1-S1-LO-A10-R?
If delta voltage transformers are used for the GE Feeder Management Relay for the relay with the part number 760-P1-G1-S1-LO-A10-R the zero sequence voltage and neutral or sensitive ground polarizing voltage will be set to zero. Also, the phase neutral voltage wont be displayed because it can't be measured with this delta voltage tranformer connection.
Is the single phase input a line voltage for the GE Feeder Management Relay 760-P1-G1-S1-LO-A10-R?
Yes, for the GE Feeder Management Relay, the single phase input is designated to a line voltage and the live voltage transformer input channel. It is used as the synchrocheck feature and can be connected to be used as phase neutral voltages and for phase to phase voltages.
For the GE Feeder Management Relay should the control power match the installed power supply range for the part number 760-P1-G1-S1-LO-A10-R?
The control power that is supplied to this GE Feeder Management Relay 760-P1-G1-S1-LO-A10-R has to match the power supply range that is installed. If the control power that's supplied doesn't match the power supply range, it can cause the unit to become damaged. No matter the control power supply type, the ground connections must also be connected for the relay to operate normally.

Reviews For 760-P1-G1-S1-LO-A10-R

Internal Review
(5.0)

The LEDs on the front of the relay can provide indications about system health and status, offering a convenient reference point for users in the vicinity. -AX Control Tech Team

Repair Services For 760-P1-G1-S1-LO-A10-R

Type Lead Time Price Action
Repair Service 1-2 weeks $1112

Our highly skilled technicians can repair your 760-P1-G1-S1-LO-A10-R. All of our repairs come with a 3 Year AX Control Warranty. Please contact us for additional information about our repair process. To receive the repair pricing and lead time listed above please process your repair order via our website. The following repair options may be available upon request:

  • 48-72hr Rush Repair
  • Detailed Repair Reports
  • AX Control Certificate of Warranty

AX Control Warranty Info

All products we sell are backed by our unparalleled warranty. A warranty certificate will be provided with your order upon request.
All PLCs, HMIs, and Turbine Control Boards: 3 Years
All AC/DC and Servo Drives: 2 Years
All Motors: 1 Year