G60-N00-HCL-F8L-H6S-M8N-P5A-UXX-WSX

    Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures
  • 4.50 (2)
  • Click a star to rate this product
    Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures
  • 4.50 (2)
  • Click a star to rate this product
Enhanced by working closely with the EnerVista UR software program, GE Multilin's G60-N00-HCL-F8L-H6S-M8N-P5A-UXX-WSX is a microprocessor-based Generator Protection System.

AVAILABILITY:

CALL FOR AVAILABILITY

Sell Surplus: Have a G60-N00-HCL-F8L-H6S-M8N-P5A-UXX-WSX to sell? Sell Now
Exchange Credit: Learn more about our exchange credit program
  • Part Number: G60-N00-HCL-F8L-H6S-M8N-P5A-UXX-WSX
  • SKU: G60N00HCLF8LH6SM8NP5AUXXWSXGM
  • Manufacturer: GE Multilin
  • Series: UR Series Universal Relays

G60-N00-HCL-F8L-H6S-M8N-P5A-UXX-WSX Technical Specifications

Fast Form-C Relay Make and Carry 0.1 A max. (resistive load)
Humidity operating up to 95%
IRIG-B Input Isolation 2 kV
Pollution Degree II
Solid-State Output Relay Maximum Voltage 265 V DC
Storage Temperature –40 to 85°C
Teleprotection CRC 32 bit

About the G60-N00-HCL-F8L-H6S-M8N-P5A-UXX-WSX

Part of General Electric Multilin’s Universal Relay series, the G60-N00-HCL-F8L-H6S-M8N-P5A-UXX-WSX is a Generator Protection System intended for medium to large generators. It adheres to all industry standards and extends asset life through its various management and safeguarding capabilities. The relay’s software is also able to update user manuals, brochures, FAQs, and more so that a user’s understanding of the relay is consistent with General Electric’s current information.

Multilin’s G60-N00-HCL-F8L-H6S-M8N-P5A-UXX-WSX offers a number of reports and tools that streamline troubleshooting processes and reduce the amount of time it takes to identify issues and inefficiencies. The Power System Troubleshooting tools are able to record operation of internal elements and external devices in the sequence of when they occur using highly accurate time-stamping. This lends users a greater understanding of system events leading up to trips and alarms, reducing overall troubleshooting time. The system can also trend and graph generator loading and performance on a user-set time scale, ranging from hours to months. Finally, the relay can evaluate generator faults using both digital and analog power system quantities, recorded at a rate of 64 samples per cycle. 

The relay works closely with Multilin’s EnerVista software program, so it is highly encouraged that users connect a computer running the software to the relay through the RS232 port located on the faceplate, the relay’s USB port, or the rear RS485 port. The software program has extremely minimal requirements for the computer running it, reducing the need for expensive hardware to support the relay. The software is easily installed from DVD or Multilin’s website, and its Plug and Play technology allows users to begin monitoring the system and conveniently editing systems quickly and efficiently. 

Frequently Asked Questions about G60-N00-HCL-F8L-H6S-M8N-P5A-UXX-WSX

What is the order code breakdown for a UR Series Multilin G60 Universal GE Relay G60-N00-HCL-F8L-H6S-M8N-P5A-UXX-WSX G60 Generator Protection System?
The UR Series Multilin G60 Universal GE Relay G60-N00-HCL-F8L-H6S-M8N-P5A-UXX-WSX G60 Generator Protection System has specific hardware and incorporated modules within the relay that is designated by looking at the model number breakdown. For example, the F8L within the model number is specifying an 8L module at the F location. The order code breakdown can shed light on what type of module that is. To start, the G60 generator protection system has the order option ‘N00’ which indicates that this unit lacks software options (00) and it has an N type CPU. Following this triad is HCL. This specifies a 19 inch horizontal mount type of G60 (H) that has an English display (C) and has a low power supply voltage capability (L). This low power supply has a voltage from 24 to 48 volts but it is only DC voltage. The 8L CT/VT module is a 4CT/4VT module with enhanced diagnostics. An 8N CT/VT module is also found in the unit, which has a standard 8CT characteristics also with the enhanced diagnostics option. The unit also contains a 5A transducer I/O module and a 6S Digital I/O module.

Reviews For G60-N00-HCL-F8L-H6S-M8N-P5A-UXX-WSX

Internal Review
(5.0)

The G60-N00-HCL-F8L-H6S-M8N-P5A-UXX-WSX offers advanced communications functions that enable the high-speed transfer of data and reduce connections required for the system. -AX Control Technicians

Repair Services For G60-N00-HCL-F8L-H6S-M8N-P5A-UXX-WSX

Type Lead Time Price Action
Repair Service 1-2 weeks $1989

Our highly skilled technicians can repair your G60-N00-HCL-F8L-H6S-M8N-P5A-UXX-WSX. All of our repairs come with a 3 Year AX Control Warranty. Please contact us for additional information about our repair process. To receive the repair pricing and lead time listed above please process your repair order via our website. The following repair options may be available upon request:

  • 48-72hr Rush Repair
  • Detailed Repair Reports
  • AX Control Certificate of Warranty

AX Control Warranty Info

All products we sell are backed by our unparalleled warranty. A warranty certificate will be provided with your order upon request.
All PLCs, HMIs, and Turbine Control Boards: 3 Years
All AC/DC and Servo Drives: 2 Years
All Motors: 1 Year
Learn More