Multilin's L90-J07-HLH-F8L-H6P-L6N-N6P-SXX-UXX-W7J is a Line Differential System that boasts metering, management, and protection capabilities in a single unit.

AVAILABILITY:

CALL FOR AVAILABILITY

Sell Surplus: Have a L90-J07-HLH-F8L-H6P-L6N-N6P-SXX-UXX-W7J to sell? Sell Now
Exchange Credit: Learn more about our exchange credit program
  • Part Number: L90-J07-HLH-F8L-H6P-L6N-N6P-SXX-UXX-W7J
  • SKU: L90J07HLHF8LH6PL6NN6PSXXUXXW7JGM
  • Manufacturer: GE Multilin
  • Series: UR Series Universal Relays

L90-J07-HLH-F8L-H6P-L6N-N6P-SXX-UXX-W7J Technical Specifications

# of FlexElements 8
LED Test Initiation from any contact input or user-programmable condition
Load Encroachment Operating Time <30 ms at 60 Hz
Maximum Altitude 2000 m
Phasor Measurement Calibration ±5° (angle) and ±5% (magnitude)
RS485 Port Isolation 2 kV, isolated together at 36 Vpk
RTD Input Sensing Current 5 mA

About the L90-J07-HLH-F8L-H6P-L6N-N6P-SXX-UXX-W7J

Boasting a combination of monitoring, metering, and safeguarding capabilities in one compact unit, GE Multilin’s L90-J07-HLH-F8L-H6P-L6N-N6P-SXX-UXX-W7J is a Line Current Differential System compatible with overhead and underground cables, circuits with trapped transformer feeders, and dual and single-breaker circuits that need autoreclosing and synchrocheck features. The relay works with lines of any voltage, and all collected data and events detected by the relay are stored for later review.

The relay’s RS232 port situated on the faceplate allows users to connect the unit to a computer running Multilin’s EnerVista UR software program, which considerably simplifies and accelerates user interactions with the system. EnerVista UR offers a suite of useful tools, including Viewpoint Engineer, Viewpoint Monitoring, Viewpoint Maintenance, and the EnerVista Integrator. The EnerVista integrator enables a stress-free integration of the relay into new or existing systems; it utilizes automatic event retrieval, automatic waveform retrieval, and downloads recent Multilin drivers in order to get the unit up and running as fast as possible. The Viewpoint Engineer tool provides a drag-and-drop interface for easy configuration and testing or the L90-J07-HLH-F8L-H6P-L6N-N6P-SXX-UXX-W7J.

The L90-J07-HLH-F8L-H6P-L6N-N6P-SXX-UXX-W7J employs GOOSE (generic object-oriented substation events) messages to eliminate hardwiring and allow for peer-to-peer wireless communication between devices. This replaces expensive copper connections, reducing installation time and costs for the user. GOOSE messages occur when a value change is detected, and the messages are retransmitted several times to ensure they reach their intended target within the system. GOOSE messages are time tagged and contain vital data.

Frequently Asked Questions about L90-J07-HLH-F8L-H6P-L6N-N6P-SXX-UXX-W7J

What type of applications is a Multilin L90-J07-HLH-F8L-H6P-L6N-N6P-SXX-UXX-W7J beneficial for?
The L90-J07-HLH-F8L-H6P-L6N-N6P-SXX-UXX-W7J is a L90 line current differential system of the Multilin universal relays. The high-speed current protection that is provided by the L90 is applicable to lines and cables with voltage levels of varying degrees. At the same time, the L90 also supports dual-breaker and complete distance applications. The protection provided is applicable to either single or to three-pole tripping situations. 
How does the L90 adjust its compensation with lines with large charging currents?
The feature that allows the L90 Multilin line current differential system to compensate for large charging currents is called charging current compensation. The current may be large in long transmission lines or in cables that run underground. In this case, the pickup settings may be excessively high. The L90 can compensate by increasing sensitivity to a fault current on these lines with the high charging current. 
What are the order specifications of the Multilin L90 Line Current Differential System GE L90-J07-HLH-F8L-H6P-L6N-N6P-SXX-UXX-W7J Universal Relay?
Following the base unit of the Multilin universal relay (L90), the J07 designation shows that the CPU is RS485 + multimode ST 100BaseFX, with the 07 software option (IEC 61850 + phasor measurement unit or PMU). 

Reviews For L90-J07-HLH-F8L-H6P-L6N-N6P-SXX-UXX-W7J

Internal Review
(5.0)

The L90-J07-HLH-F8L-H6P-L6N-N6P-SXX-UXX-W7J uses a highly effective dual phase selection algorithm to offer accurate and fast fault type identification, identifying faults and rapidly shielding system components as faults occur. -AX Control Technicians

Repair Services For L90-J07-HLH-F8L-H6P-L6N-N6P-SXX-UXX-W7J

Type Lead Time Price Action
Repair Service 1-2 weeks $1135

Our highly skilled technicians can repair your L90-J07-HLH-F8L-H6P-L6N-N6P-SXX-UXX-W7J. All of our repairs come with a 3 Year AX Control Warranty. Please contact us for additional information about our repair process. To receive the repair pricing and lead time listed above please process your repair order via our website. The following repair options may be available upon request:

  • 48-72hr Rush Repair
  • Detailed Repair Reports
  • AX Control Certificate of Warranty