GE's T60-G00-HCH-F8F-H6P-M8H-P6P-UXX-WXX Transformer Protection System offers many features in one compact unit, reducing the need for auxiliary equipment.

AVAILABILITY:

CALL FOR AVAILABILITY

Sell Surplus: Have a T60-G00-HCH-F8F-H6P-M8H-P6P-UXX-WXX to sell? Sell Now
Exchange Credit: Learn more about our exchange credit program
  • Part Number: T60-G00-HCH-F8F-H6P-M8H-P6P-UXX-WXX
  • SKU: T60G00HCHF8FH6PM8HP6PUXXWXXGM
  • Manufacturer: GE Multilin
  • Series: UR Series Universal Relays

T60-G00-HCH-F8F-H6P-M8H-P6P-UXX-WXX Technical Specifications

AC Current Withstand 20 ms at 250 times rated, 1 sec at 100 times rated
Ambient Storage Temperature –40 to 85°C
Ingress Protection IP20 front, IP10 back
Maximum Altitude 2000 m
Overvoltage Category II
RMS Voltage Accuracy ±0.5% of reading from 10 to 208 V
RTD Input Isolation 36 Vpk

About the T60-G00-HCH-F8F-H6P-M8H-P6P-UXX-WXX

General Electric Multilin’s T60-G00-HCH-F8F-H6P-M8H-P6P-UXX-WXX is a Transformer Protection Relay that can safeguard, control, and monitor small, medium, and large transformer systems. The relay offers a vast array of features in one compact unit, reducing the need for extraneous equipment and connections and saving money on both installation and wiring.

The T60-G00-HCH-F8F-H6P-M8H-P6P-UXX-WXX is complete with cyber security features that prevent unauthorized adjustments to the relay and transformer system. Dual permission access control and user command logging offer critical infrastructure protection to the relay’s network. The relay also creates a Security Audit Trail that records adjustments to the T60’s configuration, reducing the amount of work needed for cyber security audits inevitably arise. The ViewPoint maintenance tool located in Multilin’s industry-leading software program, EnerVista UR, facilitates simplified downloading of this cyber security data.

Protective elements such as overexcitation inhibiting, unrestrained differential, and percent differential protection help prolong system life by responding to faults in real time. Overexcitation resulting from decreases in system frequency or increases in transformer voltage can be addressed using a fifth harmonic inhibit included in the percent differential elements that specifically focuses on overexcitation conditions. 

The FlexLogic technology included in the relay allows for highly specific configurations of system logic. The relay allows for up to 1024 lines of code. Because complex and unusual schemes (such as interlocks or blocking) traditionally had to be hardwired in the system, the  T60-G00-HCH-F8F-H6P-M8H-P6P-UXX-WXX’s FlexLogic technology innovates on this and extends new capabilities.

Frequently Asked Questions about T60-G00-HCH-F8F-H6P-M8H-P6P-UXX-WXX

What order benefits does the T60-G00-HCH-F8F-H6P-M8H-P6P-UXX-WXX Multilin T60 transformer protection system have that differentiate it from other T60 units?
The 'H6P' shows that this T60 has 6 Form-A outputs that do not have monitoring capacity with four digital inputs in terms of its I/O specification. This T60 does not include any of the optional software options (00). 
Is the T60 able to provide diagnosis of its own health and current status to maintain optimal function?
The T60 does have health diagnostics that are used to provide advanced diagnosis of the units own health. The T60 unit runs a system health diagnostic check upon startup and during the entire time it is running in order to monitor major hardware and functions for any condition that could potentially disrupt its security or compromise protection ability.  In other words, the Multilin uses CT/VT input monitoring to make sure all signals are healthy in addition to monitoring analog channels, trip currents, and inputs or outputs. 
How does the T60-G00-HCH-F8F-H6P-M8H-P6P-UXX-WXX Multilin T60 Universal Relay for Medium and Large Power Transformer Protection perform synchronism checks?
The Multilin T60 uses six elements to measure the changes in voltage magnitude, frequencies, and phase angles. During this time, the circuit breaker closing time is taken into consideration in order to perform synchronizing checks across up to six breakers. 

Reviews For T60-G00-HCH-F8F-H6P-M8H-P6P-UXX-WXX

Internal Review
(5.0)

General Electric Multilin’s T60-G00-HCH-F8F-H6P-M8H-P6P-UXX-WXX includes an alphanumeric liquid-crystal display that can passively list system parameters when not in use, providing users in the vicinity with vital system information that can guide their efforts at any given moment. -AX Control Tech Team

Repair Services For T60-G00-HCH-F8F-H6P-M8H-P6P-UXX-WXX

Type Lead Time Price Action
Repair Service 1-2 weeks $1620

Our highly skilled technicians can repair your T60-G00-HCH-F8F-H6P-M8H-P6P-UXX-WXX. All of our repairs come with a 3 Year AX Control Warranty. Please contact us for additional information about our repair process. To receive the repair pricing and lead time listed above please process your repair order via our website. The following repair options may be available upon request:

  • 48-72hr Rush Repair
  • Detailed Repair Reports
  • AX Control Certificate of Warranty

AX Control Warranty Info

All products we sell are backed by our unparalleled warranty. A warranty certificate will be provided with your order upon request.
All PLCs, HMIs, and Turbine Control Boards: 3 Years
All AC/DC and Servo Drives: 2 Years
All Motors: 1 Year
Learn More