About the KV-40ATP
KV-40ATP has 16 transistors (SOURCE) outputs and 24 inputs for this ac type unit. The KV-40ATP is just the base unit that has AC type power. The extremely small controller is programmable by logic and has a built-in display. The consumption of the internal alternating current is at 130 mA or less for the KV-40ATP. The KV-40ATP Keyence Unit weighs around 410g. Every 11 milliseconds the 2x each of the 3 axial's conforms to JISC0041 and 150 m/s^2 or 15G. In order for the KV-40ATP to operate properly, no condensation should ever be on the unit. The humidity should stay around a 35 to 85% RH or condensation could get on the unit and damage internal components. The noise resistance is 1,500 Vp-p or more, with a pulse width of 1 µs, 50 ns (by way of a noise simulator), conforms to EN standards. Some expansion units can be installed to the KV-40ATP, including KV-E4X, KV-E8X, KV-E16X, KV-E4T, KV-E8T, KV-E16T, KV-E4R, KV-E8R, KV-E16R, KV-E4XT, KV-E4XR, and more. With an amplitude of 0.075 mm*1, the KV-40ATP can resist with a frequency of 10 or 57 Hz. For acceleration, the KV-40ATP can withstand 9.8 m/s^2*1, with a frequency of 57 or 150 Hz. The KV-40ATP can withstand up to 1,500 VAC for 1 minute of voltage between the power supply terminals and the input/output terminals and also in between all the external terminals and the case. Please refer to the users manual for programming software and installation of this PLC.