85ET4060

    Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures
  • 5.00 (3)
  • Click a star to rate this product
    Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures
  • 5.00 (3)
  • Click a star to rate this product
Model number 85ET4060 is a GV3000/SE Bookshelf Drive. The European stock number associated with this part is 896.05.31 and is made by Reliance Electric. The operating input voltage for this model is 380 to 460 VAC.

AVAILABILITY:

IN STOCK
SHIPS TODAY

Sell Surplus: Have a 85ET4060 to sell? Sell Now
Exchange Credit: Learn more about our exchange credit program
  • Part Number: 85ET4060
  • SKU: 85ET4060RE
  • Manufacturer: Reliance Electric
  • Series: GV3000 Drives

85ET4060 Technical Specifications

Part Number 85ET4060
Manufacturer Reliance Electric
Series GV3000
European Stock Number 896.05.31
Enclosure IP20
Keypad/Display Built-In Keypad
Required Firmware Version 6.0
Instruction Manual D2-3426 & D2-3427
Phase 3 Phase
Hz 60Hz
Input Voltage 380-460 VAC
Input KVA 8.0
Output Amps in Vector Mode at 8 kHz 5.0

Product Description

Model number 85ET4060 is part of the GV3000/SE series. This specific model is a bookshelf drive and was produced by Reliance Electric. The V/Hz current rating on this model is 8.5 A. The model has input KVA and input amps, the KVA input associated with this drive is 8.0, with the input amps being 10. There are different output amps depending on the regulator mode chosen to use with the 85ET4060 drive as well as three different carrier frequencies for each regulator. The carrier frequencies are 2, 4, or 8 kHz. One example of the outputs while in vector regulation at 4 kHz is 6.7 A. For all remaining output amps refer to Table 2.1 in the D2-3427-2 Manual. 

One of the components within the 85ET4060 drive is an output relay terminal strip which is located on the power board and can provide two different form contacts, form A and form B. These contacts will be under the control of the operator through the programmable parameters, the transitions regarding the form A and B contacts will be used to indicate the status of the drive. Terminals twenty-eight and thirty on the terminal strip are relay contacts, with terminals twenty-nine and thirty-one being relay commons. Please remember that the contacts on the terminal strip are rated for two amps resistive load at either 30 VDC or 250 VAC. 

The dimensions of the 85ET4060 drive are important to the installation as there are airflow requirements. The dimensions of this drive are as follows, Width Dim A 3.74”, Height Dim B 14.88”, Width Dim C 1.50”, Mounting Height Dim D 16.61”, and Depth Dim E 7.87”. 

Frequently Asked Questions about 85ET4060

What types of parameters are there on a Reliance 85ET4060?
There are three types of parameters on a Reliance 85ET4060. There are configurable parameters that can only be adjusted while 85ET4060 is stopped, there are tunable parameters that can be adjusted while 85ET4060 is running or stopped, and there are read only parameters that cannot be adjusted on 85ET4060.
What does the "FL" fault code mean on 85ET4060?
When the "FL" fault code appears on 85ET4060, it indicates a function loss on 85ET4060. This fault occurs on 85ET4060 when the function loss input on 85ET4060's control terminal is opened. To correct this fault, check the interlocks at terminals 16 and 20 on 85ET4060.
Where can I find a list of fault codes for 85ET4060?
You can find a list of fault codes in table 5.2 in the GV3000 Bookshelf Software Manual for 85ET4060 (Manual D2-3426). The table in the manual provides fault codes, fault descriptions, fault cause, and the corrective action to fix the fault on 85ET4060.
Where do I find the manuals for 85ET4060?
We can send you links to the manuals for 85ET4060. The manuals for 85ET4060 are Reliance manuals D2-3426 and D2-3427. These manuals are the software and hardware manuals for 85ET4060, respectively. The manuals will help you greatly with any tasks or issues you have with 85ET4060.

Reviews For 85ET4060

Internal Review
(5.0)

While most regulator boards in drives are inside the drive itself, the regulator board terminal strip which will hold all of the required terminals and wiring is located on the outside. The terminal strip being on the outside means that all wiring can be adjusted easily. - AX Control Technician

Repair Services For 85ET4060

Type Lead Time Price Action
Repair Service 1-2 weeks $1494

Our highly skilled technicians can repair your 85ET4060. All of our repairs come with a 3 Year AX Control Warranty. Please contact us for additional information about our repair process. To receive the repair pricing and lead time listed above please process your repair order via our website. The following repair options may be available upon request:

  • 48-72hr Rush Repair
  • Detailed Repair Reports
  • AX Control Certificate of Warranty

AX Control Warranty Info

All products we sell are backed by our unparalleled warranty. A warranty certificate will be provided with your order upon request.
All PLCs, HMIs, and Turbine Control Boards: 3 Years
All AC/DC and Servo Drives: 2 Years
All Motors: 1 Year
Learn More