6V41-8P0TA

    Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures
  • 4.5 (6)
  • Click a star to rate this product
    Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures
  • 4.5 (6)
  • Click a star to rate this product
AC Drive

AVAILABILITY:

IN STOCK
SHIPS IN 3-5 DAYS

Sell Surplus: Have a 6V41-8P0TA to sell? Sell Now
Exchange Credit: Learn more about our exchange credit program
  • Part Number: 6V41-8P0TA
  • SKU: 6V418P0TARE
  • Manufacturer: Reliance Electric
  • Series: GV6000 Drives

6V41-8P0TA Technical Specifications

Manufacturer Reliance Electric
Series GV6000
Part Number 6V41-8P0TA
HP 5 HP
Input Voltage 460 VAC
Enclosure NEMA 1 Air Cooled
Digital Input Voltage 24 VDC
Braking Transistor Included
Labeling UL Listed, IEC Certified

About the 6V41-8P0TA

6V41-8P0TA is a GV6000 AC Drive that is manufactured by Reliance Electric. The nominal duty horsepower is 5, the continuous amps are 8, and the frame is 0. The dimensions of frame 0 are 110 mm x 336 mm x 200 mm x 80 mm x 320 mm. This drive has a 460 VAC input and is enclosed in a NEMA 1 enclosure. A braking transistor comes standard on this unit. The I/O is 24 VDC.

There are a number of fault codes on the drive for troubleshooting purposes. Fault number 80 is an autotune aborted fault, means that the user canceled the autotune procedure. Restart the procedure. Fault numbers 81-85 are port 1-5 DPI loss faults. Fault number 87 is an IXo voltage range fault, which means that the volts calculated for the motor inductive impedance exceeds 25% of the motor np voltage. This fault can be corrected by checking for proper motor sizing and programming. Additional output impedance may be required. Fault number 88 and 89 are software faults. Fault number 90 is an encoder quad error fault, which means that within one clock cycle, both encoder channels changed state. Check for externally induced noise or replace the encoder. Fault number 91 is an encoder loss fault, which means that an encoder channel signal is missing. To correct this fault, check the wiring or replace the encoder. Faults can also be manually cleared via the local OIM, over a network via an attached PC, or with a clear fault command.

Frequently Asked Questions about 6V41-8P0TA

How quickly can AX Control repair my 6V41-8P0TA?
Our average repair time for a GV6000 6V41-8P0TA is about 2-3 weeks, but an expediated repair time can be requested. Call our sales representative for a repair quote and estimated repair time on your 6V41-8P0TA. 
What is the kW and HP of a 6V41-8P0TA Reliance Electric GV6000 drive at 110% OL Duty?
When a 6V41-8P0TA is at 110% OL Duty, the 6V41-8P0TA drive's kW is 4 and the 6V41-8P0TA drive's HP is 5.
Where can I find a manual for a 6V41-8P0TA?
We are happy to send you a link to the GV6000 AC Drive User Manual. The manual will provide you with all you need to know about installing, wiring, programming, and troubleshooting your 6V41-8P0TA GV6000 drive. The manual goes through parameters, the manual goes through alarms, and the manual goes through faults on GV6000 drives. The manual is not specific to a 6V41-8P0TA, but it identifies each part of a 6V41-8P0TA drive's model number.
Where are jumpers located on a 6V41-8P0TA?
Because of the zero frame size on a 6V41-8P0TA, the jumpers on the 6V41-8P0TA are the PEA- Common Mode Capacitors and PEB- MOV's. On a 6V41-8P0TA GV6000, the jumpers are located on the Power Board of the 6V41-8P0TA. To locate the jumpers, remove the I/O Cassette on the 6V41-8P0TA.
What is the width of the front panel on a 6V41-8P0TA drive?
The front panel on a GV6000 Reliance Electric 6V41-8P0TA is 4.33 inches or 110mm. For a diagram and list of all the measurements on a 6V41-8P0TA, look at section 3.1.4 in the GV6000 AC Drive User Manual. The manual lists dimensions of each part based on frame size.

Repair Services For 6V41-8P0TA

Type Lead Time Price Action
Repair Service 1-2 weeks $1790

Our highly skilled technicians can repair your 6V41-8P0TA. All of our repairs come with a 3 Year AX Control Warranty. Please contact us for additional information about our repair process. To receive the repair pricing and lead time listed above please process your repair order via our website. The following repair options may be available upon request:

  • 48-72hr Rush Repair
  • Detailed Repair Reports
  • AX Control Certificate of Warranty

AX Control Warranty Info

All products we sell are backed by our unparalleled warranty. A warranty certificate will be provided with your order upon request.
All PLCs, HMIs, and Turbine Control Boards: 3 Years
All AC/DC and Servo Drives: 2 Years
All Motors: 1 Year