In Stock
6MDAN-012101 Image One
2 year warranty

6MDAN-012101 Image 1
3HP Reliance AC Drive | Image
6MDAN-012101 Image 3

International

Phone

1-919-372-8413

Domestic (US)

1-800-991-7026

6MDAN-012101

    Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures 4.75 (4) Click a star to rate this product
    Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures
  • 4.75 (4)
  • Click a star to rate this product


3HP Reliance AC Drive

New Surplus Factory Package
$745
SKU: 2MD1
3 Year Warranty
Order Before 3PM EST
Rush Available
4 in Stock
New Surplus AX Control Package
SKU: 2MD2
3 Year Warranty
Reconditioned
SKU: 2MD3
3 Year Warranty
Repair
$441
SKU: 2MD4
3 Year Warranty

* Learn More About Product Conditions
* Posted pricing available for website purchases only.

Product Conditions

New Surplus Factory Package: A completely unused product that is in the original factory package. The package may have been opened for the purpose of pictures, but the product has never been used or installed.

New Surplus AX Control Package: A completely unused product that has been removed from the original factory package. Often due to shelf wear or previous shipping, the factory package is not adequate and must be replaced with an ideal AX Control product package.

Reconditioned: All products that qualify as reconditioned have completed AX Control's thorough and detailed QA process and meet the requirements of excellent working condition and excellent cosmetic condition.

Product Description

6MDAN-012101 is a 230V, 50/60 Hz, 1-phase MD60 Drive that is manufactured by Reliance Electric. The output current is 12.0 A and the horsepower is 3 HP. There is no filter in this drive. There are 18 display parameters on the MD60 drives. d001 is the Output Frequency, d002 is the Command Frequency, d003 is the Output Current, d004 is the Output Voltage, d005 is the DC Bus Voltage, d006 is the Drive Status, d007 is the Fault 1 Code, d008 is the Fault 2 Code, d009 is the Fault 3 Code, d010 is the Process Display, d011 does not exist, d012 is the Control Source, d013 is the Control Input Status, d014 is the Digital Input Status, d015 is the Comm Status, d016 is the Control SW Version, d017 is the drive type, d018 is the Elapsed Run Time, and d019 is the Testprint Data.

Parameters P031-P041 represent the minimum parameters required to operate the drive. P031 is the Motor NP Volts, which vary from motor to motor. P032 is the Motor NP Hertz, for which the default is 60 Hz. P033 is the Motor OL Current, which varies from motor to motor. P034 is the Minimum Frequency, for which the default is 0 Hz. P035 is the Maximum Frequency, for which the default is 60 Hz. P036 is the Start Source, for which the default is 0 (keypad). P037 is the Stop Mode, for which the default is 1 (coast, clear fault). P038 is the Speed Reference, for which the default is 0 (Drive Potentiometer). P039 is the Acceleration TIme 1, for which the default is 5.0 seconds. P040 is the Deceleration TIme 1, for which the default is 5.0 seconds. P041 is Reset to Defaults, for which the default is 0 (Idle State).

6MDAN-012101 Technical Specifications

Manufacturer Reliance Electric
Series MD60
Part Number 6MDAN-012101
HP 3 HP
Input Voltage 180-264 VAC
Enclosure NEMA 1 or Chassis
Hz 48-63Hz
kW 2.2kW
Filter/No Filter Not Filtered
Labeling UL Listed, IEC Certified

Frequently Asked Questions about 6MDAN-012101

1. What frame size is the Reliance 6MDAN-012101 drive?
The Reliance Electric 6MDAN-012101 drive has a B frame size. The 6MDAN-012101 drive is 3.94 by 8.39 inches in dimension. The drive's shipping weight is 4.9lbs.
2. What are the proper planning measures I should take before installing my 6MDAN-012101 drive?
It is important that your 6MDAN-012101 drive is installed in a safe environment. The area behind the drive must be kept clear of all control and power wiring because power connections may create interfering electromagnetic fields. Make sure to protect the drive’s cooling fan by avoiding dust or metallic particles. Do not expose the drive to a corrosive atmosphere and protect the drive from moisture and direct sunlight. Because the 6MDAN-012101 drive has a NEMA 1 Enclosure, it should be installed in a location that is kept at a minimum of 14 degrees Fahrenheit and maximum of 104 degrees Fahrenheit. The 6MDAN-012101 drive also requires clearance between drives. It is best to mount the drive on an upright, flat, and level surface.
3. Does the 6MDAN-012101 drive provide any type of circuit protection?
The MD60 6MDAN-012101 drive does not provide branch short circuit protection. You should install your 6MDAN-012101 drive with either input fuses or an input circuit breaker.
4. How does the 6MDAN-012101 drive respond to a fault?
The 6MDAN-012101 drive responds to a fault by initiating a coast-to-stop sequence and turning off output power to the motor. A fault code will appear indicating conditions within the drive that require immediate attention. The built-in keypad will show a fault condition by displaying a flashing fault number (code) and flashing FAULT LED.
5. Is there a way to set the Reliance 6MDAN-012101 drive so that it automatically clears fault codes and restarts itself to fix the problem?
To automatically clear an auto-resettable fault and restart your 6MDAN-012101 drive, set both A092 (Auto Restart Tries) and A093 (Auto Restart Delay) to a value other than 0. When a fault occurs and A092 is set to a value greater than 0, A093 begins. When the timer reaches zero, the drive will attempt to automatically reset the fault. If the condition that caused the fault is no longer present, the fault will be reset and the drive will restart. To automatically clear an OverVoltage, UnderVoltage, or Heatsink OverTemp fault without restarting the drive, set A092 to a value other than 0 and set A093 to 0. It is important to use caution when enabling this feature since the drive will attempt to issue its own start command based on user-selected programming.
6. What are the most common fault code numbers for the Reliance 6MDAN-012101 drive and what do they stand for?
-F2: Auxilary Input
-F3: Power Loss
-F4: UnderVoltage
-F5: OverVoltage
-F6: Motor Stalled
-F7: Motor Overload
-F8: Heatsink OverTemp
-F12: HW OverCurrent
-F13: Ground Fault
-F33: Auto Restart Tries
-F48: Params Defaulted
-F63: SW OverCurrent
-F64: Drive Overload
-F70: Power Unit
-F81: Comm Loss
-F100: Parameter Checksum
-F122: I/O Board Fail
7. Which fault codes on the 6MDAN-012101 drive do not have an auto-reset option?
F3, F12, F13, F33, F38-F43, F48, F64, F70, F81, F100, and F122 are the fault code numbers that do not have the ability to auto reset the drive.

6MDAN-012101 Technical Specifications

Manufacturer Reliance Electric
Series MD60
Part Number 6MDAN-012101
HP 3 HP
Input Voltage 180-264 VAC
Enclosure NEMA 1 or Chassis
Hz 48-63Hz
kW 2.2kW
Filter/No Filter Not Filtered
Labeling UL Listed, IEC Certified

Product Description

6MDAN-012101 is a 230V, 50/60 Hz, 1-phase MD60 Drive that is manufactured by Reliance Electric. The output current is 12.0 A and the horsepower is 3 HP. There is no filter in this drive. There are 18 display parameters on the MD60 drives. d001 is the Output Frequency, d002 is the Command Frequency, d003 is the Output Current, d004 is the Output Voltage, d005 is the DC Bus Voltage, d006 is the Drive Status, d007 is the Fault 1 Code, d008 is the Fault 2 Code, d009 is the Fault 3 Code, d010 is the Process Display, d011 does not exist, d012 is the Control Source, d013 is the Control Input Status, d014 is the Digital Input Status, d015 is the Comm Status, d016 is the Control SW Version, d017 is the drive type, d018 is the Elapsed Run Time, and d019 is the Testprint Data.

Parameters P031-P041 represent the minimum parameters required to operate the drive. P031 is the Motor NP Volts, which vary from motor to motor. P032 is the Motor NP Hertz, for which the default is 60 Hz. P033 is the Motor OL Current, which varies from motor to motor. P034 is the Minimum Frequency, for which the default is 0 Hz. P035 is the Maximum Frequency, for which the default is 60 Hz. P036 is the Start Source, for which the default is 0 (keypad). P037 is the Stop Mode, for which the default is 1 (coast, clear fault). P038 is the Speed Reference, for which the default is 0 (Drive Potentiometer). P039 is the Acceleration TIme 1, for which the default is 5.0 seconds. P040 is the Deceleration TIme 1, for which the default is 5.0 seconds. P041 is Reset to Defaults, for which the default is 0 (Idle State).

Frequently Asked Questions about 6MDAN-012101

1. What frame size is the Reliance 6MDAN-012101 drive?
The Reliance Electric 6MDAN-012101 drive has a B frame size. The 6MDAN-012101 drive is 3.94 by 8.39 inches in dimension. The drive's shipping weight is 4.9lbs.
2. What are the proper planning measures I should take before installing my 6MDAN-012101 drive?
It is important that your 6MDAN-012101 drive is installed in a safe environment. The area behind the drive must be kept clear of all control and power wiring because power connections may create interfering electromagnetic fields. Make sure to protect the drive’s cooling fan by avoiding dust or metallic particles. Do not expose the drive to a corrosive atmosphere and protect the drive from moisture and direct sunlight. Because the 6MDAN-012101 drive has a NEMA 1 Enclosure, it should be installed in a location that is kept at a minimum of 14 degrees Fahrenheit and maximum of 104 degrees Fahrenheit. The 6MDAN-012101 drive also requires clearance between drives. It is best to mount the drive on an upright, flat, and level surface.
3. Does the 6MDAN-012101 drive provide any type of circuit protection?
The MD60 6MDAN-012101 drive does not provide branch short circuit protection. You should install your 6MDAN-012101 drive with either input fuses or an input circuit breaker.
4. How does the 6MDAN-012101 drive respond to a fault?
The 6MDAN-012101 drive responds to a fault by initiating a coast-to-stop sequence and turning off output power to the motor. A fault code will appear indicating conditions within the drive that require immediate attention. The built-in keypad will show a fault condition by displaying a flashing fault number (code) and flashing FAULT LED.
5. Is there a way to set the Reliance 6MDAN-012101 drive so that it automatically clears fault codes and restarts itself to fix the problem?
To automatically clear an auto-resettable fault and restart your 6MDAN-012101 drive, set both A092 (Auto Restart Tries) and A093 (Auto Restart Delay) to a value other than 0. When a fault occurs and A092 is set to a value greater than 0, A093 begins. When the timer reaches zero, the drive will attempt to automatically reset the fault. If the condition that caused the fault is no longer present, the fault will be reset and the drive will restart. To automatically clear an OverVoltage, UnderVoltage, or Heatsink OverTemp fault without restarting the drive, set A092 to a value other than 0 and set A093 to 0. It is important to use caution when enabling this feature since the drive will attempt to issue its own start command based on user-selected programming.
6. What are the most common fault code numbers for the Reliance 6MDAN-012101 drive and what do they stand for?
-F2: Auxilary Input
-F3: Power Loss
-F4: UnderVoltage
-F5: OverVoltage
-F6: Motor Stalled
-F7: Motor Overload
-F8: Heatsink OverTemp
-F12: HW OverCurrent
-F13: Ground Fault
-F33: Auto Restart Tries
-F48: Params Defaulted
-F63: SW OverCurrent
-F64: Drive Overload
-F70: Power Unit
-F81: Comm Loss
-F100: Parameter Checksum
-F122: I/O Board Fail
7. Which fault codes on the 6MDAN-012101 drive do not have an auto-reset option?
F3, F12, F13, F33, F38-F43, F48, F64, F70, F81, F100, and F122 are the fault code numbers that do not have the ability to auto reset the drive.