In Stock
6MDAN-1P5101 Image One
2 year warranty

6MDAN-1P5101 Image 1
RELIANCE ELECTRIC AC DRIVE 1/4HP 230VAC 1PHASE MD60 | Image
6MDAN-1P5101 Image 3

International

Phone

1-919-372-8413

Domestic (US)

1-800-991-7026

6MDAN-1P5101

    Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures 4.75 (4) Click a star to rate this product
    Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures
  • 4.75 (4)
  • Click a star to rate this product


RELIANCE ELECTRIC AC DRIVE 1/4HP 230VAC 1PHASE MD60

New Surplus Factory Package
$375
SKU: 4MD1
3 Year Warranty
Order Before 3PM EST
Rush Available
1 in Stock
New Surplus AX Control Package
SKU: 4MD2
3 Year Warranty
Reconditioned
SKU: 4MD3
3 Year Warranty
Repair
$363
SKU: 4MD4
3 Year Warranty

* Learn More About Product Conditions
* Posted pricing available for website purchases only.

Product Conditions

New Surplus Factory Package: A completely unused product that is in the original factory package. The package may have been opened for the purpose of pictures, but the product has never been used or installed.

New Surplus AX Control Package: A completely unused product that has been removed from the original factory package. Often due to shelf wear or previous shipping, the factory package is not adequate and must be replaced with an ideal AX Control product package.

Reconditioned: All products that qualify as reconditioned have completed AX Control's thorough and detailed QA process and meet the requirements of excellent working condition and excellent cosmetic condition.

Product Description

6MDAN-1P5101 is a 230V, 50/60 Hz, 1-phase MD60 Drive that is manufactured by Reliance Electric. The output current is 1.5 A, the horsepower is 0.25 HP, and the output power is 0.2 kW. There is no filter in this drive. The frame size is A. The recommended fuse type is UL Class J, CC, T, or Type BS88; 600 V (550 V) or equivalent. The carrier frequency is 2-16 kHz, and the drive rating is based upon 4 kHz. The digital input accuracy is accurate within ± 0.05% of the set output frequency. The analog input is accurate within 0.5% of the maximum output frequency. The speed regulation (open loop with slip compensation) is accurate within ± 2% of the base speed across a 40:1 speed range. There are multiple programmable stop modes: ramp, coast, DC-brake, ramp-to-hold, and S-curve. The acceleration and deceleration times are independently programmable. The electronic motor overload protection is Class 10 protection with speed-sensitive response.

There are many protective features on the MD60 drive, including the bus overvoltage trip, the bus undervoltage trip, the software current limit, the hardware current limit, the instantaneous current limit, the power dip ride-through, and the fault-free ride through. Options available with the MD60 drive include: the NEMA 1 kit, AC input mains filters (for EMC compliance), the Dynamic Braking Resistor kit, a remote mount NEMA 4 operator keypad, a handheld programmer (for setting, uploading, and downloading parameters), and a cable option that allows the MD60 to connect to a PC running V*S Utilities configuration software.

6MDAN-1P5101 Technical Specifications

Manufacturer Reliance Electric
Series MD60
Part Number 6MDAN-1P5101
HP 0.25 HP
Input Voltage 240 VAC
Enclosure NEMA 1 or Chassis
Hz 50/60Hz
kW 0.2kW
Filter/No Filter Not Filtered
Labeling UL Listed, IEC Certified

Frequently Asked Questions about 6MDAN-1P5101

What output current is a Reliance Electric MD60 6MDAN-1P5101 drive?
Because the 6MDAN-1P5101 drive has a 230 VAC input voltage with 50/60Hz and no filter, it is a 1 phase drive with an output current of 1.5A. As the kW and HP increase on 230 VAC drives with 50/60Hz and no filter, the output current increases. The 1.5A output current of the 6MDAN-1P5101 drive matches the output current of any 115 VAC or 230 VAC drive that has a 0.2kW and 0.25HP rating, but it does not match any 460 VAC rated drives.
Where should I store my Reliance 6MDAN-1P5101 drive for a long period of time?
It is best not to store a 6MDAN-1P5101 drive for too long, but we offer recomendations if needed. To prolong drive life and performance of your 6MDAN-1P5101 drive, make sure to store the drive within an ambient temperature range of -40 degrees Celsius to 85 degrees Celsius. You should store your 6MDAN-1P5101 drive within a relative humidty of 0 to 95 percent, non-condensing, and you should make sure your 6MDAN-1P5101 drive is not exposed to a corrosive atmosphere.
Is there a recommended mounting clearance on the 6MDAN-1P5101 drive?
The 6MDAN-1P5101 drive has a NEMA 1 enclosure type which means clearance is needed between drives. The MD60 AC Drive User Manual displays a mounting clearance chart under its "Recommended Mounting Clearances" section. AX Control is happy to provide you with a link to this manual. According to the manual, only mounting option A requires no clearance between drives. Since 6MDAN-1P5101 has a minimum ambient temperature of -10 degrees Celsius and a maximum ambient temperature of 40 degrees Celsius with a NEMA 1 enclosure, it must follow mounting option B in the manual. Only drives with those ambient temperatures and an enclosure rating of IP20 can follow mounting option A which doesn't require clearance.
What preparation measures should I take if I plan to keep my 6MDAN-1P5101 drive inside a cabinet?
It is best if your 6MDAN-1P5101 drive is grounded for maximum performance. If you plan to install your 6MDAN-1P5101 drive on an ungrounded system such as a cabinet, you should connect building steel directly to a single safety ground point or ground bus bar to get as close to being grounded as possible. All circuits connected to your 6MDAN-1P5101 drive including the AC input ground conductor should be grounded independently and directly to the ground point or ground bus bar.
How do I open the cover on my MD60 6MDAN-1P5101 drive?
To open the cover on your MD60 6MDAN-1P5101 drive, press and hold in the tabs on each side of the cover. Once the buttons are pushed in, pull the cover of your 6MDAN-1P5101 drive out and up to release and take off the cover.
What should I do if my input power line on my 6MDAN-1P5101 drive has frequent interruptions?
There are two options to correct the input power line condition on your 6MDAN-1P5101 MD60 drive.You can install a line reactor on your 6MDAN-1P5101 drive, or you can install an isolation transformer for your 6MDAN-1P5101 drive.
Where should I look if I have more in-depth questions about my Reliance Electric 6MDAN-1P5101 drive?
For a detailed guide of all MD60 drives, you can view the MD60 AC Drive User Manual that AX Control will be happy to send you the link to. Within the manual, you will find answers to more in-depth questions. You can also find questions and pairings particular to your 6MDAN-1P5101 drive. If you want more assistance, AX Control is also happy to help you over the phone at 919-372-8413.
What are the most commonly used parameters on the 6MDAN-1P5101 drive?
As described in the MD60 AC Drive User Manual, the Basic Program Group contains the most commonly used parameters to simplify the start-up process for your 6MDAN-1P5101 drive. These parameters are P031-P036 and they deal with the motor NP volts and hertz, motor OL current, minimum and maximum frequencies, and start source. For a more detailed description and visual aid, look at the MD60 AC Drive Manual.

6MDAN-1P5101 Technical Specifications

Manufacturer Reliance Electric
Series MD60
Part Number 6MDAN-1P5101
HP 0.25 HP
Input Voltage 240 VAC
Enclosure NEMA 1 or Chassis
Hz 50/60Hz
kW 0.2kW
Filter/No Filter Not Filtered
Labeling UL Listed, IEC Certified

Product Description

6MDAN-1P5101 is a 230V, 50/60 Hz, 1-phase MD60 Drive that is manufactured by Reliance Electric. The output current is 1.5 A, the horsepower is 0.25 HP, and the output power is 0.2 kW. There is no filter in this drive. The frame size is A. The recommended fuse type is UL Class J, CC, T, or Type BS88; 600 V (550 V) or equivalent. The carrier frequency is 2-16 kHz, and the drive rating is based upon 4 kHz. The digital input accuracy is accurate within ± 0.05% of the set output frequency. The analog input is accurate within 0.5% of the maximum output frequency. The speed regulation (open loop with slip compensation) is accurate within ± 2% of the base speed across a 40:1 speed range. There are multiple programmable stop modes: ramp, coast, DC-brake, ramp-to-hold, and S-curve. The acceleration and deceleration times are independently programmable. The electronic motor overload protection is Class 10 protection with speed-sensitive response.

There are many protective features on the MD60 drive, including the bus overvoltage trip, the bus undervoltage trip, the software current limit, the hardware current limit, the instantaneous current limit, the power dip ride-through, and the fault-free ride through. Options available with the MD60 drive include: the NEMA 1 kit, AC input mains filters (for EMC compliance), the Dynamic Braking Resistor kit, a remote mount NEMA 4 operator keypad, a handheld programmer (for setting, uploading, and downloading parameters), and a cable option that allows the MD60 to connect to a PC running V*S Utilities configuration software.

Frequently Asked Questions about 6MDAN-1P5101

What output current is a Reliance Electric MD60 6MDAN-1P5101 drive?
Because the 6MDAN-1P5101 drive has a 230 VAC input voltage with 50/60Hz and no filter, it is a 1 phase drive with an output current of 1.5A. As the kW and HP increase on 230 VAC drives with 50/60Hz and no filter, the output current increases. The 1.5A output current of the 6MDAN-1P5101 drive matches the output current of any 115 VAC or 230 VAC drive that has a 0.2kW and 0.25HP rating, but it does not match any 460 VAC rated drives.
Where should I store my Reliance 6MDAN-1P5101 drive for a long period of time?
It is best not to store a 6MDAN-1P5101 drive for too long, but we offer recomendations if needed. To prolong drive life and performance of your 6MDAN-1P5101 drive, make sure to store the drive within an ambient temperature range of -40 degrees Celsius to 85 degrees Celsius. You should store your 6MDAN-1P5101 drive within a relative humidty of 0 to 95 percent, non-condensing, and you should make sure your 6MDAN-1P5101 drive is not exposed to a corrosive atmosphere.
Is there a recommended mounting clearance on the 6MDAN-1P5101 drive?
The 6MDAN-1P5101 drive has a NEMA 1 enclosure type which means clearance is needed between drives. The MD60 AC Drive User Manual displays a mounting clearance chart under its "Recommended Mounting Clearances" section. AX Control is happy to provide you with a link to this manual. According to the manual, only mounting option A requires no clearance between drives. Since 6MDAN-1P5101 has a minimum ambient temperature of -10 degrees Celsius and a maximum ambient temperature of 40 degrees Celsius with a NEMA 1 enclosure, it must follow mounting option B in the manual. Only drives with those ambient temperatures and an enclosure rating of IP20 can follow mounting option A which doesn't require clearance.
What preparation measures should I take if I plan to keep my 6MDAN-1P5101 drive inside a cabinet?
It is best if your 6MDAN-1P5101 drive is grounded for maximum performance. If you plan to install your 6MDAN-1P5101 drive on an ungrounded system such as a cabinet, you should connect building steel directly to a single safety ground point or ground bus bar to get as close to being grounded as possible. All circuits connected to your 6MDAN-1P5101 drive including the AC input ground conductor should be grounded independently and directly to the ground point or ground bus bar.
How do I open the cover on my MD60 6MDAN-1P5101 drive?
To open the cover on your MD60 6MDAN-1P5101 drive, press and hold in the tabs on each side of the cover. Once the buttons are pushed in, pull the cover of your 6MDAN-1P5101 drive out and up to release and take off the cover.
What should I do if my input power line on my 6MDAN-1P5101 drive has frequent interruptions?
There are two options to correct the input power line condition on your 6MDAN-1P5101 MD60 drive.You can install a line reactor on your 6MDAN-1P5101 drive, or you can install an isolation transformer for your 6MDAN-1P5101 drive.
Where should I look if I have more in-depth questions about my Reliance Electric 6MDAN-1P5101 drive?
For a detailed guide of all MD60 drives, you can view the MD60 AC Drive User Manual that AX Control will be happy to send you the link to. Within the manual, you will find answers to more in-depth questions. You can also find questions and pairings particular to your 6MDAN-1P5101 drive. If you want more assistance, AX Control is also happy to help you over the phone at 919-372-8413.
What are the most commonly used parameters on the 6MDAN-1P5101 drive?
As described in the MD60 AC Drive User Manual, the Basic Program Group contains the most commonly used parameters to simplify the start-up process for your 6MDAN-1P5101 drive. These parameters are P031-P036 and they deal with the motor NP volts and hertz, motor OL current, minimum and maximum frequencies, and start source. For a more detailed description and visual aid, look at the MD60 AC Drive Manual.