6MDAN-2P3101
-
4.75 (4)
Click a star to rate this product
- 4.75 (4)
- Click a star to rate this product
Reliance AC Drive MD60 Series
* Learn More About Product Conditions
* Posted pricing available for website purchases only.
Product Conditions
New Surplus Factory Package: A completely unused product that is in the original factory package. The package may have been opened for the purpose of pictures, but the product has never been used or installed.
New Surplus AX Control Package: A completely unused product that has been removed from the original factory package. Often due to shelf wear or previous shipping, the factory package is not adequate and must be replaced with an ideal AX Control product package.
Reconditioned: All products that qualify as reconditioned have completed AX Control's thorough and detailed QA process and meet the requirements of excellent working condition and excellent cosmetic condition.
About the 6MDAN-2P3101
6MDAN-2P3101 is a 230 V, 50/60 Hz, 1-phase MD60 Drive that is manufactured by Reliance Electric. The output current is 2.3 A, the horsepower is 0.5 HP, and the output power is 0.37 kW. There is no filter in this drive. The frame size is A.The drive should be mounted upright on a flat, vertical and level surface, either on a panel with screws or on a 35 mm DIN rail. The drive can be protected from debris with a plastic top panel. The drive must be grounded before it can be power wired for installation. Verify that the drive AC input ratings match the available power. When the power wire rating is unshielded 600V, 75° C THHN/THWN, the recommended copper wire is 15 mils insulated. When the power wire rating is shielded 600V, 90° RHH/RHW-2, the recommended copper wire is Belden 29501-29507 or equivalent. When the power wire rating is shielded tray rated 600V, 90° C RHH/RHW-2, the recommended copper wire is Showflex 2 ACD/3 ACD (or equivalent).
The drive is intended to be commanded by control input signals that will start and stop the motor. A device that routinely disconnects then reapplies output power to the motor for the purpose of starting and stopping the motor should not be used. If it is necessary to disconnect power to the motor while the drive is providing output power, an auxiliary contact should be used to simultaneously disable drive control run commands. Check the installation before you apply power to the drive. All inputs must be connected to the correct terminals, check that AC power matches the drive rating, check that external control power is 24 VDC. Power up the drive.
6MDAN-2P3101 Manuals, White Papers, Data Sheets, and Troubleshooting
6MDAN-2P3101 Technical Specifications
Manufacturer | Reliance Electric |
Series | MD60 |
Part Number | 6MDAN-2P3101 |
HP | 0.5 HP |
Input Voltage | 180-264 VAC |
Enclosure | NEMA 1 or Chassis |
Hz | 48-63Hz |
kW | 0.4kW |
Filter/No Filter | Not Filtered |
Labeling | UL Listed, IEC Certified |
Frequently Asked Questions about 6MDAN-2P3101
What phase is the 6MDAN-2P3101 MD60 drive?
What should I know if I want to I/O wire my 6MDAN-2P3101?
How do I know I installed a 6MDAN-2P3101 drive correctly?
What troubleshooting options are available for my 6MDAN-2P3101?
How fast can my 6MDAN-2P3101 be shipped?
What does the symbol of a circle inside of a square mean on 6MDAN-2P3101?
Does the 6MDAN-2P3101 have a filter?
6MDAN-2P3101 Technical Specifications
Manufacturer | Reliance Electric |
Series | MD60 |
Part Number | 6MDAN-2P3101 |
HP | 0.5 HP |
Input Voltage | 180-264 VAC |
Enclosure | NEMA 1 or Chassis |
Hz | 48-63Hz |
kW | 0.4kW |
Filter/No Filter | Not Filtered |
Labeling | UL Listed, IEC Certified |
About the 6MDAN-2P3101
6MDAN-2P3101 is a 230 V, 50/60 Hz, 1-phase MD60 Drive that is manufactured by Reliance Electric. The output current is 2.3 A, the horsepower is 0.5 HP, and the output power is 0.37 kW. There is no filter in this drive. The frame size is A.The drive should be mounted upright on a flat, vertical and level surface, either on a panel with screws or on a 35 mm DIN rail. The drive can be protected from debris with a plastic top panel. The drive must be grounded before it can be power wired for installation. Verify that the drive AC input ratings match the available power. When the power wire rating is unshielded 600V, 75° C THHN/THWN, the recommended copper wire is 15 mils insulated. When the power wire rating is shielded 600V, 90° RHH/RHW-2, the recommended copper wire is Belden 29501-29507 or equivalent. When the power wire rating is shielded tray rated 600V, 90° C RHH/RHW-2, the recommended copper wire is Showflex 2 ACD/3 ACD (or equivalent).
The drive is intended to be commanded by control input signals that will start and stop the motor. A device that routinely disconnects then reapplies output power to the motor for the purpose of starting and stopping the motor should not be used. If it is necessary to disconnect power to the motor while the drive is providing output power, an auxiliary contact should be used to simultaneously disable drive control run commands. Check the installation before you apply power to the drive. All inputs must be connected to the correct terminals, check that AC power matches the drive rating, check that external control power is 24 VDC. Power up the drive.