6MDBN-012101
-
4.80 (5)
Click a star to rate this product
- 4.80 (5)
- Click a star to rate this product
RELIANCE ELECTRIC DRIVE 3HP 230VOLT 3PHASE IP20 MD60
* Learn More About Product Conditions
* Posted pricing available for website purchases only.
Product Conditions
New Surplus Factory Package: A completely unused product that is in the original factory package. The package may have been opened for the purpose of pictures, but the product has never been used or installed.
New Surplus AX Control Package: A completely unused product that has been removed from the original factory package. Often due to shelf wear or previous shipping, the factory package is not adequate and must be replaced with an ideal AX Control product package.
Reconditioned: All products that qualify as reconditioned have completed AX Control's thorough and detailed QA process and meet the requirements of excellent working condition and excellent cosmetic condition.
About the 6MDBN-012101
6MDBN-012101 is a 230 V, 50/60 Hz, 3-phase MD60 Drive that is manufactured by Reliance Electric. The output current is 12.0 A, the horsepower is 3.0, and the output power is 2.2 kW. There is no filter in this drive. The frame size is B. The possible causes when the drive does not start from Terminal Block Start or Run Inputs include the following: a faulted drive, incorrect programming, incorrect input wiring. The possible causes when the drive does not start from Integral keypad include: a non-enabled integral keypad, a not-present I/O terminal 01 “Stop”. The possible causes when the drive does not respond to changes in Speed Command include: the source of the command is not producing a value, an incorrect reference source is being selected via remote device or digital inputs.
The possible causes when the motor and/or the drive will not accelerate to commanded speed include: an excessive acceleration time, excess load or short acceleration times force the drive into current limit, slowing, or stopping acceleration, there is an unexpected speed command source or value, the drive output cannot exceed limiting values due to the programming. The possible cause when the motor operation is unstable is that the motor data was incorrectly entered. The possible causes when the drive will not reverse the motor direction include: the reverse is disabled, the motor wiring is improperly phased, the digital input is incorrectly wired, and the digital input is not selected for reversing control.
6MD20003
The 6MD20003 module was produced by Reliance Electric for the MD-60 series as an AC drive. 6MD20003 is the catalog number for the AC drive model number 6MDBN-012101. The majority of the time, you will find the 6MD20003 AC drive inside of our stock at AX Control due to our efforts to supply it for the convenience of our customers.
The 6MD20003 AC drive is a 3 phase drive with a motor rating of 2.2 kW and 3.0 HP. The input for the 6MD20003 AC drive is rated as being of 200 to 240 V and 48 to 63 Hz, with an AC voltage range of 180 to 264 V and an amperage rating of 15.5 A. The output, on the other hand, is rated as being 0 to 240 Hz, with an AC voltage range of 0 to 230 V, a continuous amperage rating of 12.0 A and a 60 sec ovid amperage rating of 18.0 A.
The 6MD20003 AC drive’s faceplate has a small LCD display at the top, which can indicate different kinds of information to the operator. Below the display, there is a small dial and numerous buttons that the operator will use to control the LCD display and the functions of the drive.
On one side of the 6MD20003 AC drive, there is a label that outlines the different codes that can appear on the LCD display. On the left side of this label, there is a list of all of the drive’s fault codes. On the right side of this label, there is a list of all of the drive’s common parameters.
6MDBN-012101 Technical Specifications
Manufacturer | Reliance Electric |
Series | MD60 |
Part Number | 6MDBN-012101 |
HP | 3 HP |
Input Voltage | 180-264 VAC |
Enclosure | NEMA 1 or Chassis |
Hz | 48-63Hz |
kW | 2.2kW |
Filter/No Filter | Not Filtered |
Labeling | UL Listed, IEC Certified |
Frequently Asked Questions about 6MDBN-012101
What phase is the 6MDBN-012101 Reliance Electric MD60 drive?
What are the output rating amps for a 6MDBN-012101 drive?
What is the power dissipation for a MD60 Reliance Electric 6MDBN-012101?
What is the branch circuit protection fuse rating for a 6MDBN-012101?
How can I command the drive speed on a 6MDBN-012101?
Does AX Control have reconditioned 6MDBN-012101 drives?
6MDBN-012101 Technical Specifications
Manufacturer | Reliance Electric |
Series | MD60 |
Part Number | 6MDBN-012101 |
HP | 3 HP |
Input Voltage | 180-264 VAC |
Enclosure | NEMA 1 or Chassis |
Hz | 48-63Hz |
kW | 2.2kW |
Filter/No Filter | Not Filtered |
Labeling | UL Listed, IEC Certified |
About the 6MDBN-012101
6MDBN-012101 is a 230 V, 50/60 Hz, 3-phase MD60 Drive that is manufactured by Reliance Electric. The output current is 12.0 A, the horsepower is 3.0, and the output power is 2.2 kW. There is no filter in this drive. The frame size is B. The possible causes when the drive does not start from Terminal Block Start or Run Inputs include the following: a faulted drive, incorrect programming, incorrect input wiring. The possible causes when the drive does not start from Integral keypad include: a non-enabled integral keypad, a not-present I/O terminal 01 “Stop”. The possible causes when the drive does not respond to changes in Speed Command include: the source of the command is not producing a value, an incorrect reference source is being selected via remote device or digital inputs.
The possible causes when the motor and/or the drive will not accelerate to commanded speed include: an excessive acceleration time, excess load or short acceleration times force the drive into current limit, slowing, or stopping acceleration, there is an unexpected speed command source or value, the drive output cannot exceed limiting values due to the programming. The possible cause when the motor operation is unstable is that the motor data was incorrectly entered. The possible causes when the drive will not reverse the motor direction include: the reverse is disabled, the motor wiring is improperly phased, the digital input is incorrectly wired, and the digital input is not selected for reversing control.
6MD20003
The 6MD20003 module was produced by Reliance Electric for the MD-60 series as an AC drive. 6MD20003 is the catalog number for the AC drive model number 6MDBN-012101. The majority of the time, you will find the 6MD20003 AC drive inside of our stock at AX Control due to our efforts to supply it for the convenience of our customers.
The 6MD20003 AC drive is a 3 phase drive with a motor rating of 2.2 kW and 3.0 HP. The input for the 6MD20003 AC drive is rated as being of 200 to 240 V and 48 to 63 Hz, with an AC voltage range of 180 to 264 V and an amperage rating of 15.5 A. The output, on the other hand, is rated as being 0 to 240 Hz, with an AC voltage range of 0 to 230 V, a continuous amperage rating of 12.0 A and a 60 sec ovid amperage rating of 18.0 A.
The 6MD20003 AC drive’s faceplate has a small LCD display at the top, which can indicate different kinds of information to the operator. Below the display, there is a small dial and numerous buttons that the operator will use to control the LCD display and the functions of the drive.
On one side of the 6MD20003 AC drive, there is a label that outlines the different codes that can appear on the LCD display. On the left side of this label, there is a list of all of the drive’s fault codes. On the right side of this label, there is a list of all of the drive’s common parameters.