6MDBN-1P5101
-
5.00 (3)
Click a star to rate this product
- 5.00 (3)
- Click a star to rate this product
RELIANCE ELECTRIC DRIVE 1/4HP 230V 1PHASE IP20 MD60
* Learn More About Product Conditions
* Posted pricing available for website purchases only.
Product Conditions
New Surplus Factory Package: A completely unused product that is in the original factory package. The package may have been opened for the purpose of pictures, but the product has never been used or installed.
New Surplus AX Control Package: A completely unused product that has been removed from the original factory package. Often due to shelf wear or previous shipping, the factory package is not adequate and must be replaced with an ideal AX Control product package.
Reconditioned: All products that qualify as reconditioned have completed AX Control's thorough and detailed QA process and meet the requirements of excellent working condition and excellent cosmetic condition.
About the 6MDBN-1P5101
6MDBN-1P5101 is a 230 V, 50/60 Hz, 3-phase MD60 Drive that is manufactured by Reliance Electric. The output current is 1.5 A, the horsepower is 0.25 HP, and the output power is 0.2 kW. There is no filter in this drive. The frame size is A. There are many protective features on the MD60 drive, including the bus overvoltage trip, the bus undervoltage trip, the software current limit, the hardware current limit, the instantaneous current limit, the power dip ride-through, and the fault-free ride through.
There are a number of fault codes that may appear on the drive. Fault code F2 is an auxiliary input fault. This auto-resettable fault occurs when the auxiliary input interlock is open. In order to correct this fault, check the remote wiring and check the communications programming for an intentional fault. Fault code F3 is a power loss fault. This fault is not auto-resettable, and it occurs when the DC bus voltage is below 85% of the nominal bus voltage. In order to correct this fault, monitor the incoming AC line for a line power interruption or for low voltage. Also, check the input fuses. Fault code F4 is an undervoltage fault. This auto-resettable fault occurs when the DC bus voltage falls below the minimum DC bus voltage value. In order to correct this fault, check the incoming AC line for a line power interruption or for low voltage. Fault code F5 is an overvoltage fault. This auto-resettable fault occurs when the DC bus voltage rises above the maximum DC bus voltage value. In order to correct this fault, check the incoming AC line for transient conditions or for high line voltage.
6MD200P2
The 6MD200P2 unit is an AC drive for the MD-60 series, which was made by the company Reliance Electric. 6MD200P2 is the catalog number for the model number 6MDBN-1P5101. Most of the time, you will be able to find the 6MD200P2 AC drive in our stock, thanks to our efforts to stock this series for our customers.
The 6MD200P2 AC drive is one of the MD-60 product series’ three phase drives. This particular drive has a motor rating of 0.2 kW and 0.25 HP. The drive’s input is rated as 200 through 240 V and 48 through 63 Hz. The AC voltage range is 180 through 264 V. Also, the 6MD200P2 AC drive’s input is rated as having 1.8 A. The output of the 6MD200P2 AC drive, on the other hand, has between 0 and 240 Hz and a voltage range of 0 through 230 V. The 60 sec ovid Amps for the 6MD200P2 AC drive is 2.25 A and the continuous Amps is 1.5 A.
On the front of the 6MD200P2 AC drive, there is a small LCD display at the top. The LCD display indicates Volts, Amps, and Hertz for the various functions of the drive, which are RUN, REV, and FWD. Below the LCD display, there are numerous buttons and a small dial that are used to control the drive’s functions and the display.
When ready to install the 6MD200P2 AC drive, be sure that you use either a 35 mm DIN rail or a panel with a thickness of at least 1.9 mm using an M4 screw. The drive comes with a plastic panel that can be installed on the drive. This panel prevents debris from falling into the drive’s vents.
6MDBN-1P5101 Technical Specifications
Manufacturer | Reliance Electric |
Series | MD60 |
Part Number | 6MDBN-1P5101 |
HP | 0.25 HP |
Input Voltage | 180-264 VAC |
Enclosure | NEMA 1 or Chassis |
Hz | 48-63Hz |
kW | 0.2kW |
Filter/No Filter | Not Filtered |
Labeling | UL Listed, IEC Certified |
Frequently Asked Questions about 6MDBN-1P5101
How should I verify the condition of the installation of my 6MDBN-1P5101 drive?
1. Make sure all inputs are securely connected to the proper terminals on the 6MDBN-1P5101.
2. Check that the AC line power at the disconnect device is within the rated value of the 6MDBN-1P5101 drive.
3. Be sure that any external digital control power is 24 volts DC.
4. Verify the SNK/SRC Setup DIP Switch is set to match the control wiring scheme on your 6MDBN-1P5101 drive.
What phase is the 6MDBN-1P5101?
Does AX Control have new surplus of 6MDBN-1P5101 drives?
What does the F6 fault code mean on a 6MDBN-1P5101?
Where can I find a manual for my 6MDBN-1P5101 drive?
6MDBN-1P5101 Technical Specifications
Manufacturer | Reliance Electric |
Series | MD60 |
Part Number | 6MDBN-1P5101 |
HP | 0.25 HP |
Input Voltage | 180-264 VAC |
Enclosure | NEMA 1 or Chassis |
Hz | 48-63Hz |
kW | 0.2kW |
Filter/No Filter | Not Filtered |
Labeling | UL Listed, IEC Certified |
About the 6MDBN-1P5101
6MDBN-1P5101 is a 230 V, 50/60 Hz, 3-phase MD60 Drive that is manufactured by Reliance Electric. The output current is 1.5 A, the horsepower is 0.25 HP, and the output power is 0.2 kW. There is no filter in this drive. The frame size is A. There are many protective features on the MD60 drive, including the bus overvoltage trip, the bus undervoltage trip, the software current limit, the hardware current limit, the instantaneous current limit, the power dip ride-through, and the fault-free ride through.
There are a number of fault codes that may appear on the drive. Fault code F2 is an auxiliary input fault. This auto-resettable fault occurs when the auxiliary input interlock is open. In order to correct this fault, check the remote wiring and check the communications programming for an intentional fault. Fault code F3 is a power loss fault. This fault is not auto-resettable, and it occurs when the DC bus voltage is below 85% of the nominal bus voltage. In order to correct this fault, monitor the incoming AC line for a line power interruption or for low voltage. Also, check the input fuses. Fault code F4 is an undervoltage fault. This auto-resettable fault occurs when the DC bus voltage falls below the minimum DC bus voltage value. In order to correct this fault, check the incoming AC line for a line power interruption or for low voltage. Fault code F5 is an overvoltage fault. This auto-resettable fault occurs when the DC bus voltage rises above the maximum DC bus voltage value. In order to correct this fault, check the incoming AC line for transient conditions or for high line voltage.
6MD200P2
The 6MD200P2 unit is an AC drive for the MD-60 series, which was made by the company Reliance Electric. 6MD200P2 is the catalog number for the model number 6MDBN-1P5101. Most of the time, you will be able to find the 6MD200P2 AC drive in our stock, thanks to our efforts to stock this series for our customers.
The 6MD200P2 AC drive is one of the MD-60 product series’ three phase drives. This particular drive has a motor rating of 0.2 kW and 0.25 HP. The drive’s input is rated as 200 through 240 V and 48 through 63 Hz. The AC voltage range is 180 through 264 V. Also, the 6MD200P2 AC drive’s input is rated as having 1.8 A. The output of the 6MD200P2 AC drive, on the other hand, has between 0 and 240 Hz and a voltage range of 0 through 230 V. The 60 sec ovid Amps for the 6MD200P2 AC drive is 2.25 A and the continuous Amps is 1.5 A.
On the front of the 6MD200P2 AC drive, there is a small LCD display at the top. The LCD display indicates Volts, Amps, and Hertz for the various functions of the drive, which are RUN, REV, and FWD. Below the LCD display, there are numerous buttons and a small dial that are used to control the drive’s functions and the display.
When ready to install the 6MD200P2 AC drive, be sure that you use either a 35 mm DIN rail or a panel with a thickness of at least 1.9 mm using an M4 screw. The drive comes with a plastic panel that can be installed on the drive. This panel prevents debris from falling into the drive’s vents.
Frequently Asked Questions about 6MDBN-1P5101
How should I verify the condition of the installation of my 6MDBN-1P5101 drive?
1. Make sure all inputs are securely connected to the proper terminals on the 6MDBN-1P5101.
2. Check that the AC line power at the disconnect device is within the rated value of the 6MDBN-1P5101 drive.
3. Be sure that any external digital control power is 24 volts DC.
4. Verify the SNK/SRC Setup DIP Switch is set to match the control wiring scheme on your 6MDBN-1P5101 drive.