6MD200 AC Drive by Reliance Rockwell Automation
* Learn More About Product Conditions
* Posted pricing available for website purchases only.
Product Conditions
New Surplus Factory Package: A completely unused product that is in the original factory package. The package may have been opened for the purpose of pictures, but the product has never been used or installed.
New Surplus AX Control Package: A completely unused product that has been removed from the original factory package. Often due to shelf wear or previous shipping, the factory package is not adequate and must be replaced with an ideal AX Control product package.
Reconditioned: All products that qualify as reconditioned have completed AX Control's thorough and detailed QA process and meet the requirements of excellent working condition and excellent cosmetic condition.
About the 6MDBN-2P3101
6MDBN-2P3101 is a 230 V, 50/60 Hz, 3-phase MD60 Drive that is manufactured by Reliance Electric. The output current is 2.3 A, the horsepower is 0.5 HP, and the output power is 0.37 kW. There is no filter in this drive. The frame size is A. When installing the drive, keep it protected with a cooling fan (to avoid dust and metallic particles). Do not expose the drive to a corrosive atmosphere, moisture, or direct sunlight. The enclosure rating can be either IP20/Open Type or IP30/ NEMA 1/ ULType 1.
There are a number of fault codes that may appear on the drive. Fault code F6 is a motor stalled fault. This auto-resettable fault means that the drive is not able to accelerate the motor. In order to correct this fault, either increase the acceleration time or reduce the load on the motor. Fault code F7 is a motor overload fault. This auto-resettable fault occurs when there is an internal electronic overload trip. This fault can be corrected by reducing the load on the motor. Also, verify the Start Boost setting. Fault code F8 is a heatsink overtemp fault. This auto-resettable fault means that the predefined heatsink temperature value has been exceeded. This fault can be corrected by clearing dirty or blocked heat sink fins and/or checking the fan. Fault code F12 is a HW overcurrent fault. This fault is not auto-resettable, and it occurs when the drive output current has exceeded the hardware current limit. This fault can be corrected by checking the programming and checking for excess load.
6MDBN-2P3101 Manuals, White Papers, Data Sheets, and Troubleshooting
6MDBN-2P3101 Technical Specifications
Manufacturer | Reliance Electric |
Series | MD60 |
Part Number | 6MDBN-2P3101 |
HP | 0.5 HP |
Input Voltage | 180-264 VAC |
Enclosure | NEMA 1 or Chassis |
Hz | 48-63Hz |
kW | 0.4kW |
Filter/No Filter | Not Filtered |
Labeling | UL Listed, IEC Certified |
Frequently Asked Questions about 6MDBN-2P3101
Is there a manual for the MD60 6MDBN-2P3101 drive?
What frame size is the MD60 Reliance Electric 6MDBN-2P3101?
What is the output current on a 6MDBN-2P3101 MD60 drive?
What phase is the 6MDBN-2P3101?
Where do I find parameter descriptions for my 6MDBN-2P3101 drive?
6MDBN-2P3101 Technical Specifications
Manufacturer | Reliance Electric |
Series | MD60 |
Part Number | 6MDBN-2P3101 |
HP | 0.5 HP |
Input Voltage | 180-264 VAC |
Enclosure | NEMA 1 or Chassis |
Hz | 48-63Hz |
kW | 0.4kW |
Filter/No Filter | Not Filtered |
Labeling | UL Listed, IEC Certified |
About the 6MDBN-2P3101
6MDBN-2P3101 is a 230 V, 50/60 Hz, 3-phase MD60 Drive that is manufactured by Reliance Electric. The output current is 2.3 A, the horsepower is 0.5 HP, and the output power is 0.37 kW. There is no filter in this drive. The frame size is A. When installing the drive, keep it protected with a cooling fan (to avoid dust and metallic particles). Do not expose the drive to a corrosive atmosphere, moisture, or direct sunlight. The enclosure rating can be either IP20/Open Type or IP30/ NEMA 1/ ULType 1.
There are a number of fault codes that may appear on the drive. Fault code F6 is a motor stalled fault. This auto-resettable fault means that the drive is not able to accelerate the motor. In order to correct this fault, either increase the acceleration time or reduce the load on the motor. Fault code F7 is a motor overload fault. This auto-resettable fault occurs when there is an internal electronic overload trip. This fault can be corrected by reducing the load on the motor. Also, verify the Start Boost setting. Fault code F8 is a heatsink overtemp fault. This auto-resettable fault means that the predefined heatsink temperature value has been exceeded. This fault can be corrected by clearing dirty or blocked heat sink fins and/or checking the fan. Fault code F12 is a HW overcurrent fault. This fault is not auto-resettable, and it occurs when the drive output current has exceeded the hardware current limit. This fault can be corrected by checking the programming and checking for excess load.