6MDDN-1P4101
-
4.56 (9)
Click a star to rate this product
- 4.56 (9)
- Click a star to rate this product
Reliance Electric MD60 6MDDN-1P4101 .5HP 460V AC Drive
* Learn More About Product Conditions
* Posted pricing available for website purchases only.
Product Conditions
New Surplus Factory Package: A completely unused product that is in the original factory package. The package may have been opened for the purpose of pictures, but the product has never been used or installed.
New Surplus AX Control Package: A completely unused product that has been removed from the original factory package. Often due to shelf wear or previous shipping, the factory package is not adequate and must be replaced with an ideal AX Control product package.
Reconditioned: All products that qualify as reconditioned have completed AX Control's thorough and detailed QA process and meet the requirements of excellent working condition and excellent cosmetic condition.
About the 6MDDN-1P4101
6MDDN-1P4101 is a 460 V, 50/60 Hz, 3-phase MD60 Drive that is manufactured by Reliance Electric. The output current is 1.4 A, the horsepower is 0.5 HP, and the output power is 0.37 kW. A is the frame size, and this particular drive does not have a filter. There are many protective features on the MD60 drive, including the bus overvoltage trip, the bus undervoltage trip, the software current limit, the hardware current limit, the instantaneous current limit, the power dip ride-through, and the fault-free ride through. Do not attempt to operate this drive unless you are qualified electrical personnel with knowledge of the equipment.
There are a number of fault codes that may appear on the drive. Fault code F70 is a power unit fault, which means that an error has been detected in the power section of the drive. This fault is not auto-resettable but can be corrected by cycling power or replacing the drive if it cannot be cleared. Fault code F81 is a communication loss fault, which means that port RS485 stopped communicating. Check the port wiring and the connection. A module may have been intentionally disconnected from the port. Fault code F100 is a parameter checksum fault, which means that the checksum read from the board does not match the checksum calculated. Reset the defaults on the drive to clear this fault, as it is not auto-resettable. Fault code F122 is an I/O board failure. To correct this fault, cycle the drive power. If the fault does not clear, replace the drive.
6MDDN-1P4101 Manuals, White Papers, Data Sheets, and Troubleshooting
6MDDN-1P4101 Technical Specifications
Manufacturer | Reliance Electric |
Series | MD60 |
Part Number | 6MDDN-1P4101 |
HP | 0.5 HP |
Input Voltage | 342-528 VAC |
Enclosure | NEMA 1 or Chassis |
Hz | 48-63Hz |
kW | 0.4kW |
Filter/No Filter | Not Filtered |
Labeling | UL Listed, IEC Certified |
Frequently Asked Questions about 6MDDN-1P4101
How does a Reliance MD60 6MDDN-1P4101 respond to a fault error?
How do you enable external dynamic braking on a MD60 6MDDN-1P4101 drive?
How can I find out what fault code numbers and parameter values stand for on a 6MDDN-1P4101?
What does the F70 fault code error stand for on a 6MDDN-1P4101?
6MDDN-1P4101 Technical Specifications
Manufacturer | Reliance Electric |
Series | MD60 |
Part Number | 6MDDN-1P4101 |
HP | 0.5 HP |
Input Voltage | 342-528 VAC |
Enclosure | NEMA 1 or Chassis |
Hz | 48-63Hz |
kW | 0.4kW |
Filter/No Filter | Not Filtered |
Labeling | UL Listed, IEC Certified |
About the 6MDDN-1P4101
6MDDN-1P4101 is a 460 V, 50/60 Hz, 3-phase MD60 Drive that is manufactured by Reliance Electric. The output current is 1.4 A, the horsepower is 0.5 HP, and the output power is 0.37 kW. A is the frame size, and this particular drive does not have a filter. There are many protective features on the MD60 drive, including the bus overvoltage trip, the bus undervoltage trip, the software current limit, the hardware current limit, the instantaneous current limit, the power dip ride-through, and the fault-free ride through. Do not attempt to operate this drive unless you are qualified electrical personnel with knowledge of the equipment.
There are a number of fault codes that may appear on the drive. Fault code F70 is a power unit fault, which means that an error has been detected in the power section of the drive. This fault is not auto-resettable but can be corrected by cycling power or replacing the drive if it cannot be cleared. Fault code F81 is a communication loss fault, which means that port RS485 stopped communicating. Check the port wiring and the connection. A module may have been intentionally disconnected from the port. Fault code F100 is a parameter checksum fault, which means that the checksum read from the board does not match the checksum calculated. Reset the defaults on the drive to clear this fault, as it is not auto-resettable. Fault code F122 is an I/O board failure. To correct this fault, cycle the drive power. If the fault does not clear, replace the drive.