6MDVN-2P3101

    Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures 4.71 (7) Click a star to rate this product
    Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures
  • 4.71 (7)
  • Click a star to rate this product


1 Phase 0.5HP 6MD100P5

New Surplus Factory Package
SKU: 25MD1
2 Year Warranty:
New Surplus AX Control Package
SKU: 25MD2
2 Year Warranty:
Reconditioned
SKU: 25MD3
2 Year Warranty:
Repair
$344
SKU: 25MD4
2 Year Warranty:

* Learn More About Product Conditions
* Posted pricing available for website purchases only.

Product Conditions

New Surplus Factory Package: A completely unused product that is in the original factory package. The package may have been opened for the purpose of pictures, but the product has never been used or installed.

New Surplus AX Control Package: A completely unused product that has been removed from the original factory package. Often due to shelf wear or previous shipping, the factory package is not adequate and must be replaced with an ideal AX Control product package.

Reconditioned: All products that qualify as reconditioned have completed AX Control's thorough and detailed QA process and meet the requirements of excellent working condition and excellent cosmetic condition.

About the 6MDVN-2P3101

6MDVN-2P3101 is a Reliance Electric 115V, 50/60 Hz, 1-phase drive that is part of the MD60 drive series. This drive has 0.37 kW, a horsepower rating of 0.5, and an output current of 2.3 A. The frame size is A. There are a number of parameters on the MD60 drive. Parameter A106 is the Comm Loss Time. The default is 5.0, and the range is 0.1 to 60.0. Parameter A107 is the Comm Format. The default is 0 (RTU 8-N-1). The range includes 0 (RTU 8-N-1), 1 (RTU 8-E-1), 2 (RTU 8-O-1), 3 (RTU 8-N-2), 4 (RTU 8-E-2), and 5 (RTU 8-O-2). Parameter A110 is the 0-10 V Analog Input Lo. The default is 0.0% and the range is 0.0 to 100.0%. Parameter A111 is the 0-10 V Analog Input High. The default is 100.0% and the range is 0.0 to 100.0%. Parameter A112 is the 4-20 mA Analog Input Low. The default is 0.0% and the range is 0.0 to 100.0%. Parameter A113 is the 4-20 mA Analog Input High. The default is 100.0% and the range is 0.0 to 100.0%. Parameter A114 is the Slip Compensation. The default is 2.0 Hz and the range is 0.0 to 10.0 Hz. Parameter A115 is the Process Time Lo. The default is 0.00 and the range is 0.0 to 99.99. Parameter A116 is the Process Time Hi. The default is 0.00 and the range is 0.0 to 99.99. Each of these parameters may be manually altered on the drive.

6MDVN-2P3101 Manuals, White Papers, Data Sheets, and Troubleshooting

6MDVN-2P3101 Technical Specifications

Manufacturer Reliance Electric
Series MD60
Part Number 6MDVN-2P3101
HP 0.5 HP
Input Voltage 90-132 VAC
Enclosure NEMA 1 or Chassis
Hz 48-63Hz
kW 0.4kW
Filter/No Filter Not Filtered
Labeling UL Listed, IEC Certified

Frequently Asked Questions about 6MDVN-2P3101

What does the F8 fault code error mean on a 6MDVN-2P3101?
The F8 fault code is the Heatsink OverTemp fault code error. When you see the F8 fault code appear on a MD60 Reliance Electric 6MDVN-2P3101, the heatsink temperature has exceeded the predefined value of 104 degrees Farenheit for a MD60 6MDVN-2P3101 drive. To correct this fault on your 6MDVN-2P3101, check for blocked or dirty heat sink fins and check the fan on your 6MDVN-2P3101. 
Which fault codes cannot be set on auto-reset mode on a MD60 6MDVN-2P3101 drive?
On a 6MDVN-2P3101, you can't set fault codes F3, F12, F13, F33, F38, F39, F40, F41, F42, F43, F48, F64, F70, F81, F100, or F122 to auto-reset mode. These fault codes must be manually cleared.
What protective features does a Reliance Electric MD60 6MDVN-2P3101 have?
MD60 drives have several protective features. They include: Motor Protection, Overcurrent, Over Voltage, Under Voltage, Control Ride-Through, and Faultless Power Ride-Through. For descriptions of the protective features, ask us to send you the link to the MD60 AC Drive User Manual. 
What is the output current on a 6MDVN-2P3101?
6MDVN-2P3101 drives have an output current of 2.3 amps. 
What is the shipping weight of a 6MDVN-2P3101?
MD60 Reliance Electric 6MDVN-2P3101 drives have an A frame size so a 6MDVN-2P3101 has a shipping weight of 3.1lbs. 

6MDVN-2P3101 Technical Specifications

Manufacturer Reliance Electric
Series MD60
Part Number 6MDVN-2P3101
HP 0.5 HP
Input Voltage 90-132 VAC
Enclosure NEMA 1 or Chassis
Hz 48-63Hz
kW 0.4kW
Filter/No Filter Not Filtered
Labeling UL Listed, IEC Certified

About the 6MDVN-2P3101

6MDVN-2P3101 is a Reliance Electric 115V, 50/60 Hz, 1-phase drive that is part of the MD60 drive series. This drive has 0.37 kW, a horsepower rating of 0.5, and an output current of 2.3 A. The frame size is A. There are a number of parameters on the MD60 drive. Parameter A106 is the Comm Loss Time. The default is 5.0, and the range is 0.1 to 60.0. Parameter A107 is the Comm Format. The default is 0 (RTU 8-N-1). The range includes 0 (RTU 8-N-1), 1 (RTU 8-E-1), 2 (RTU 8-O-1), 3 (RTU 8-N-2), 4 (RTU 8-E-2), and 5 (RTU 8-O-2). Parameter A110 is the 0-10 V Analog Input Lo. The default is 0.0% and the range is 0.0 to 100.0%. Parameter A111 is the 0-10 V Analog Input High. The default is 100.0% and the range is 0.0 to 100.0%. Parameter A112 is the 4-20 mA Analog Input Low. The default is 0.0% and the range is 0.0 to 100.0%. Parameter A113 is the 4-20 mA Analog Input High. The default is 100.0% and the range is 0.0 to 100.0%. Parameter A114 is the Slip Compensation. The default is 2.0 Hz and the range is 0.0 to 10.0 Hz. Parameter A115 is the Process Time Lo. The default is 0.00 and the range is 0.0 to 99.99. Parameter A116 is the Process Time Hi. The default is 0.00 and the range is 0.0 to 99.99. Each of these parameters may be manually altered on the drive.

6MDVN-2P3101 Manuals, White Papers, Data Sheets, and Troubleshooting

Frequently Asked Questions about 6MDVN-2P3101

What does the F8 fault code error mean on a 6MDVN-2P3101?
The F8 fault code is the Heatsink OverTemp fault code error. When you see the F8 fault code appear on a MD60 Reliance Electric 6MDVN-2P3101, the heatsink temperature has exceeded the predefined value of 104 degrees Farenheit for a MD60 6MDVN-2P3101 drive. To correct this fault on your 6MDVN-2P3101, check for blocked or dirty heat sink fins and check the fan on your 6MDVN-2P3101. 
Which fault codes cannot be set on auto-reset mode on a MD60 6MDVN-2P3101 drive?
On a 6MDVN-2P3101, you can't set fault codes F3, F12, F13, F33, F38, F39, F40, F41, F42, F43, F48, F64, F70, F81, F100, or F122 to auto-reset mode. These fault codes must be manually cleared.
What protective features does a Reliance Electric MD60 6MDVN-2P3101 have?
MD60 drives have several protective features. They include: Motor Protection, Overcurrent, Over Voltage, Under Voltage, Control Ride-Through, and Faultless Power Ride-Through. For descriptions of the protective features, ask us to send you the link to the MD60 AC Drive User Manual. 
What is the output current on a 6MDVN-2P3101?
6MDVN-2P3101 drives have an output current of 2.3 amps. 
What is the shipping weight of a 6MDVN-2P3101?
MD60 Reliance Electric 6MDVN-2P3101 drives have an A frame size so a 6MDVN-2P3101 has a shipping weight of 3.1lbs.