6MDBN-5P0102 Technical Specifications

Manufacturer Reliance Electric
Series MD65
Part Number 6MDBN-5P0102
HP 1HP
Input Voltage 230 VAC
Hz 50/60Hz
kW 0.75kW

About the 6MDBN-5P0102

6MDBN-5P0102 is a 200-240 VAC 3-phase input, 0-230 V 3-phase output MD65 drive that is manufactured by Reliance Electric. This drive outputs 0.75 kW (1.0 HP) and 5.0 amps. The input voltage range is 180-265, the input kVA is 2.45, and the input amps are 5.7. The branch circuit protection is 10 for the fuses and 15 for the circuit breaker. The power dissipation is 55 watts. The team at AX Control is ready to answer any questions you may have about this part or its associated series.

There are a number of drive faults that can be troubleshooted. F70 is a power unit fault, which means that the drive power section has failed. To correct this fault, cycle the drive power. If the fault cannot be cleared, the user must replace the drive. F80 is an SVC autotune fault, which means the autotune function was either cancelled by the user or failed. To correct this fault, complete the restart procedure. F81 is the comm loss fault, which means that communication stopped on the RS485 port. To correct this fault, check the wiring and the connection, or turn off using Comm Loss Action (A105). F100 is a parameter checksum fault, which means that the checksum calculated does not match the checksum read from the board. To correct this fault, set the reset to defaults parameter (P041) to 1 (Reset Defaults). F122 is an I/O board failure fault, which means that there is a failure in the drive control and I/O section. To correct this fault, cycle the drive power. If the fault cannot be cleared, the user must replace the drive.

Frequently Asked Questions about 6MDBN-5P0102

Is the 6MDBN-5P0102 equipped with programmable preset speeds?
The 6MDBN-5P0102 is equipped with eight programmable preset speeds. 
What temperature should the 6MDBN-5P0102 be kept at?
The 6MDBN-5P0102 should be stored somewhere with a temperature between 14-104 degrees fahrenheight. 
Where can I find the manual for the 6MDBN-5P0102?
The 6MDBN-5P0102 is included in the MD-65 Series manual that has detailed information on the series and models. You can find the MD-65 manual on our website, axcontrol.com. 
What are some features included in the 6MDBN-5P0102?
The 6MDBN-5P0102 comes equipped with multiple features such as auto restart, input voltage tolerance, and eight programmable preset speeds. 

Repair Services For 6MDBN-5P0102

Type Lead Time Price Action
Repair Service 1-2 weeks $399

Our highly skilled technicians can repair your 6MDBN-5P0102. All of our repairs come with a 3 Year AX Control Warranty. Please contact us for additional information about our repair process. To receive the repair pricing and lead time listed above please process your repair order via our website. The following repair options may be available upon request:

  • 48-72hr Rush Repair
  • Detailed Repair Reports
  • AX Control Certificate of Warranty

AX Control Warranty Info

All products we sell are backed by our unparalleled warranty. A warranty certificate will be provided with your order upon request.
All PLCs, HMIs, and Turbine Control Boards: 3 Years
All AC/DC and Servo Drives: 2 Years
All Motors: 1 Year
Learn More