S20-401P3B1000 Technical Specifications

Manufacturer Reliance Electric
Series SP200
Part Number S20-401P3B1000
HP 0.5 HP
Input Voltage 380-480 VAC
Enclosure Protected Chassis (IP 20)
Labeling UL Listed, IEC Certified
Model Preset Speed

About the S20-401P3B1000

Reliance Electric manufactures S20-401P3B1000, an SP200 AC drive with a 3-phase 380-480V input and a 3-phase 460V output. This preset speed drive is rated 0.5 HP. The rated input current is 1.5 amperes, the rated output current is 1.3 amperes, and the fuse rating is 3 or 4 amperes. The circuit breaker rating is 3 amperes, and the typical power loss is 25 watts.

This equipment should only be installed, adjusted, operated, and or serviced by qualified electrical personnel familiar with the construction and operation of these units. Always wait three minutes after disconnecting input power to ensure that DC bus capacitors are discharged. Always stay clear of a running motor if it must be exposed to check the direction of rotation. Disconnect, lockout, and tag the power source if contact must be made. As the user, ensure that you are conforming with all national and local electrical codes before proceeding with installation of the equipment. Failure to adhere to any of the aforementioned safety warnings may result in severe bodily injury or loss of life. The instruction manual Quick Start guide is intended for experienced users only.

The recommended fuse type is a UL Class J or CC, 600V, time delay fuse. The device must meet UL 489 standards for UL purposes. When mounting the drives, the top and bottom clearance must be 38.1 mm (1.5 in), and the side clearance must be 25.4 mm (1.0 in) on the right of the drive when installation/removal of the local keypad is required.

Repair Services For S20-401P3B1000

Type Lead Time Price Action
Repair Service 1-2 weeks $527

Our highly skilled technicians can repair your S20-401P3B1000. All of our repairs come with a 3 Year AX Control Warranty. Please contact us for additional information about our repair process. To receive the repair pricing and lead time listed above please process your repair order via our website. The following repair options may be available upon request:

  • 48-72hr Rush Repair
  • Detailed Repair Reports
  • AX Control Certificate of Warranty

AX Control Warranty Info

All products we sell are backed by our unparalleled warranty. A warranty certificate will be provided with your order upon request.
All PLCs, HMIs, and Turbine Control Boards: 3 Years
All AC/DC and Servo Drives: 2 Years
All Motors: 1 Year
Learn More