1SU54002

    Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures
  • 4.67 (9)
  • Click a star to rate this product
    Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures
  • 4.67 (9)
  • Click a star to rate this product
Reliance SP500 575V NEMA 4 AC Controller.

AVAILABILITY:

IN STOCK
SHIPS TODAY

Sell Surplus: Have a 1SU54002 to sell? Sell Now
Exchange Credit: Learn more about our exchange credit program
  • Part Number: 1SU54002
  • SKU: 1SU54002RE
  • Manufacturer: Reliance Electric
  • Series: SP500 AC Drives

1SU54002 Technical Specifications

Manufacturer Reliance Electric
Series SP500
Part Number 1SU54002
HP 2 HP
Input Voltage 575 VAC
Enclosure NEMA 4X (Indoor Only)/NEMA 12
Hz 50/60Hz
Labeling UL Listed, IEC Certified

About the 1SU54002

1SU54002 is an SP500 drive that is manufactured by Reliance Electric. This drive has a 575 VAC and is enclosed in a NEMA 4X (indoor only)/NEMA 12 enclosure. The horsepower rating is 2.0 HP. This SP500 drive is contained in a size B enclosure. The dimensions of Enclosure B are 301.7 mm (11.88 in) (H) x 160.1 mm (6.3 in) (D) x 222.3 mm (8.75 in) (W). The weight of enclosure B is 5.4 kg (12 lb).

The drive may display a number of fault codes in order to indicate that a fault has occurred. CHS is the code for the default parameter restore fault (checksum error). This fault is caused by a regulator board failure during drive operation. In order to correct this fault, replace the regulator board. If replacing the regulator board does not correct the fault, contact the supplier. EC is the code for the earth current failure fault (ground fault). This fault is caused by unintentional grounding. In order to correct this fault, check the isolation between the ground and the output terminals. If there is possible leakage or current sensor defects, the sensor must be replaced to correct the fault. EEr is the code for the non-volatile memory write failure fault. This fault is caused by a failure of the drive to write to non-volatile memory.. In order to correct this fault, upload parameters via CS3000 software, or record parameters by hand. Then replace the regulator board. Remember that when the power is cycled after replacing the regulator board, parameter values will be lost.

Frequently Asked Questions about 1SU54002

Is there a manual for the Reliance 1SU54002?
Yes. We can send you a link to the manual for 1SU54002. The manual is the SP500 AC Drive Installation and Operation Manual - Manual D2-3356. The manual will help with installing and operating a Reliance 1SU54002 as well as troubleshooting 1SU54002.
What are the input and output amps on 1SU54002?
1SU54002 has 3.4 input amps. 1SU54002 has 2.7 output amps.
Is 1SU54002 vented?
No 1SU54002 is a non-vented drive. We know 1SU54002 is non-vented because of the 4X/12 enclosure rating on a Reliance 1SU54002.

Repair Services For 1SU54002

Type Lead Time Price Action
Repair Service 1-2 weeks $917

Our highly skilled technicians can repair your 1SU54002. All of our repairs come with a 3 Year AX Control Warranty. Please contact us for additional information about our repair process. To receive the repair pricing and lead time listed above please process your repair order via our website. The following repair options may be available upon request:

  • 48-72hr Rush Repair
  • Detailed Repair Reports
  • AX Control Certificate of Warranty

AX Control Warranty Info

All products we sell are backed by our unparalleled warranty. A warranty certificate will be provided with your order upon request.
All PLCs, HMIs, and Turbine Control Boards: 3 Years
All AC/DC and Servo Drives: 2 Years
All Motors: 1 Year
Learn More

1SU54002 Manuals, White Papers, Data Sheets, and Troubleshooting