UVZ-3455 Power Unit Inspector by Reliance Electric from VZ3000 Series Drive

AVAILABILITY:

IN STOCK
SHIPS TODAY

Sell Surplus: Have a UVZ-3455 to sell? Sell Now
Exchange Credit: Learn more about our exchange credit program
  • Part Number: UVZ-3455
  • SKU: UVZ3455RE
  • Manufacturer: Reliance Electric
  • Series: VZ3000 Series

UVZ-3455 Technical Specifications

Manufacturer Reliance Electric
Series VZ3000
Part Number UVZ-3455
Input Voltage 400 V
Enclosure Chassis
Phase 3 Phase
kW 55 kW
Hz 0/120Hz
Type Inverter Unit (including Bus Unit, IGBT Unit, Regulator Unit, and peripherals)

Product Description

The UVZ-3455 is a VZ3000 3-Phase 55 kW Inverter Unit that was produced by Reliance Electric.

The UVZ-3455 includes a regulator unit, a Bus Unit (UBZ3455), and an IGBT unit (UGZ3455). This unit is not used in a parallel drive unit. This unit has a 400 V power supply voltage. It has an input of 460-700 VDC and 119 amps with an output of 0-120 Hz, 0-460 VDC, and 140 amps.  It uses basic software SF-F173BC and should be used with motor VMWGF405515. The communications baud rate is 9600. It has a 3 kHz carrier frequency and can overload at 150% for 1 minute. This unit has the ability to produce 2200 watts of heat. The Bus/IGBT portion of this unit is 1173 mm tall, 210 mm wide, 335 mm thick, and 27 kg. The regulator portion of this unit is 75 mm wide, 435 mm tall, 265 mm thick, and weighs 2.5 kg.

The UVZ-3455 is in a chassis-type enclosure. It should be mounted into a control cabinet in an environment that has a 5-95% humidity rate and in temperatures that are between -10 to +55 degrees Celsius. The environment should be free of corrosive or flammable gas, direct sunlight, dust, metal powder, or condensation/water.

When mounting the UVZ-3455, the Bus unit should be located under a duct unit in the cabinet. The IGBT unit should be connected to the Bus unit using copper bars and mounted directly below it. The regulator unit goes on the left side of the IGBT unit.

For more information about the UVZ-3455 and all of the units associated with it, please refer to the Reliance instruction manual 32022-12E.

Frequently Asked Questions about UVZ-3455

How should you set the jumpers on a Reliance UVZ-3455?
Jumpers JP1 and JP2 on a UVZ-3455 set gain of feedback current on the UVZ-3455. The jumpers on a UVZ-3455 should be set to open because of the UVZ-3455 model unit.
Where can I find a manual for this Reliance Electrice UVZ-3455 drive?
We will be more than happy to send a link to the manual for this drive UVZ-3455 through our email, sales@axcontrol.com. Please send a request for the manual with the title as "VZ3000 380-460 VAC Drive Hardware Reference, Installation, Start-up, and Troubleshooting" and we will gladly send a link for this manual.
What is the cooling method on a Reliance UVZ-3455?
UVZ-3455 is a forced cooled type inverter. UVZ-3455 is cooled with a DC brushless fan.

Repair Services For UVZ-3455

Type Lead Time Price Action
Repair Service 1-2 weeks $3664

Our highly skilled technicians can repair your UVZ-3455. All of our repairs come with a 3 Year AX Control Warranty. Please contact us for additional information about our repair process. To receive the repair pricing and lead time listed above please process your repair order via our website. The following repair options may be available upon request:

  • 48-72hr Rush Repair
  • Detailed Repair Reports
  • AX Control Certificate of Warranty

AX Control Warranty Info

All products we sell are backed by our unparalleled warranty. A warranty certificate will be provided with your order upon request.
All PLCs, HMIs, and Turbine Control Boards: 3 Years
All AC/DC and Servo Drives: 2 Years
All Motors: 1 Year
Learn More